Evidence map›Paper›PMID 31766391›Full record

ArticleSensors (Basel, Switzerland)2019

Measurement of Pulse Wave Signals and Blood Pressure by a Plastic Optical Fiber FBG Sensor.

Yuki Haseda, Julien Bonefacino, Hwa-Yaw Tam, Shun Chino, Shouhei Koyama, Hiroaki Ishizawa

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Review
  9. Article
  10. Review
  11. Smart Sensors for Healthcare and Medical Applications.Sensors (Basel, Switzerland) · 2021
    Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuki HasedaGratuate School of Medicine, Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan.
Julien BonefacinoDepartment of Electrical Engineering, Photonics Research Centre, The Hong Kong Polytechnic University, 11 Yuk Choi Road, Hung Hom, Kowloon, Hong Kong, China.
Hwa-Yaw TamDepartment of Electrical Engineering, Photonics Research Centre, The Hong Kong Polytechnic University, 11 Yuk Choi Road, Hung Hom, Kowloon, Hong Kong, China.
Shun ChinoInterdisciplinary Graduate School of Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan.
Shouhei KoyamaFaculty of Textile Science and Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan.ORCID 0000-0003-4297-7648
Hiroaki IshizawaInstitute for Fiber Engineering, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan.

Funding

General Research Fund Project PolyU 152207/18EJapan Society for the Promotion of Science JP16H01805PolyU Central Grant project 1-ZVGBProgram on Open Innovation Platform with Enterprises, Research Institute and Academia JPMJOP1722
6 · The paper itself

Abstract

Fiber Bragg grating (FBG) sensors fabricated in silica optical fiber (Silica-FBG) have been used to measure the strain of human arteries as pulse wave signals. A variety of vital signs including blood pressure can be derived from these signals. However, silica optical fiber presents a safety risk because it is easily fractured. In this research, an FBG sensor fabricated in plastic optical fiber (POF-FBG) was employed to resolve this problem. Pulse wave signals were measured by POF-FBG and silica-FBG sensors for four subjects. After signal processing, a calibration curve was constructed by partial least squares regression, then blood pressure was calculated from the calibration curve. As a result, the POF-FBG sensor could measure the pulse wave signals with an signal to noise (SN) ratio at least eight times higher than the silica-FBG sensor. Further, the measured signals were substantially similar to those of an acceleration plethysmograph (APG). Blood pressure is measured with low error, but the POF-FBG APG correlation is distributed from 0.54 to 0.72, which is not as high as desired. Based on these results, pulse wave signals should be measured under a wide range of reference blood pressures to confirm the reliability of blood pressure measurement uses POF-FBG sensors.

Indexed as

AlgorithmsBlood PressureBlood Pressure DeterminationCalibrationHeart RateHumansLeast-Squares AnalysisOptical FibersPhysical PhenomenaPlasticsReproducibility of ResultsSignal Processing, Computer-AssistedPlasticsblood pressurefiber Bragg gratingnon-invasive measurementpartial least squares regressionplastic optical fiberpulse wave signals

Identifiers

PMID31766391
PMCPMC6928766

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked