Evidence map›Paper›PMID 31766200›Full record

ArticleSensors (Basel, Switzerland)2019

MEMS-Based Sensor for Simultaneous Measurement of Pulse Wave and Respiration Rate.

Thanh-Vinh Nguyen, Masaaki Ichiki

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 2 pooled it
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 2 syntheses or guidelines pooled it, 38 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Thanh-Vinh NguyenSensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Ibaraki 305-8564, Japan.
Masaaki IchikiSensing System Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Ibaraki 305-8564, Japan.
National Institute of Advanced Industrial Science and Technology · JP

Funding

Japan Society for the Promotion of Science 17H04903
6 · The paper itself

Abstract

The continuous measurements of vital signs (body temperature, blood pressure, pulse wave, and respiration rate) are important in many applications across various fields, including healthcare and sports. To realize such measurements, wearable devices that cause minimal discomfort to the wearers are highly desired. Accordingly, a device that can measure multiple vital signs simultaneously using a single sensing element is important in order to reduce the number of devices attached to the wearer's body, thereby reducing user discomfort. Thus, in this study, we propose a device with a microelectromechanical systems (MEMS)-based pressure sensor that can simultaneously measure the blood pulse wave and respiration rate using only one sensing element. In particular, in the proposed device, a thin silicone tube, whose inner pressure can be measured via a piezoresistive cantilever, is attached to the nose pad of a pair of eyeglasses. On wearing the eyeglasses, the tube of sensor device is in contact with the area above the angular artery and nasal cavity of the subject, and thus, both pulse wave and breath of the subject cause the tube's inner pressure to change. We experimentally show that it is possible to extract information related to pulse wave and respiration as the low-frequency and high-frequency components of the sensor signal, respectively.

Indexed as

AdultCalibrationHeart RateHumansMaleMicro-Electrical-Mechanical SystemsMiddle AgedPulse Wave AnalysisRespiratory Ratecantilevermicroelectromechanical systems (MEMS)piezoresistivepulse waverespirationtube

Identifiers

PMID31766200
PMCPMC6891372
OpenAlexW2984179980

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.