Evidence map›Paper›PMID 31766178›Full record

ArticleSensors (Basel, Switzerland)2019

A Microfluidic Prototype System towards Microalgae Cell Separation, Treatment and Viability Characterization.

Yanjuan Wang, Junsheng Wang, Chen Zhou, Gege Ding, Mengmeng Chen, Jiang Zou, Ge Wang, Yuejun Kang, Xinxiang Pan

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.5field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.

  1. Pooled it
  2. Marine Sensors: Recent Advances and Challenges.Sensors (Basel, Switzerland) · 2023
    Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Yanjuan WangCenter of Microfluidic and Optoelectronic Sensing, Dalian Maritime University, Dalian 116026, China.ORCID 0000-0003-0812-5732
Junsheng WangCenter of Microfluidic and Optoelectronic Sensing, Dalian Maritime University, Dalian 116026, China.
Chen ZhouCenter of Microfluidic and Optoelectronic Sensing, Dalian Maritime University, Dalian 116026, China.
Gege DingCenter of Microfluidic and Optoelectronic Sensing, Dalian Maritime University, Dalian 116026, China.
Mengmeng ChenCenter of Microfluidic and Optoelectronic Sensing, Dalian Maritime University, Dalian 116026, China.
Jiang ZouCenter of Microfluidic and Optoelectronic Sensing, Dalian Maritime University, Dalian 116026, China.
Ge WangCenter of Microfluidic and Optoelectronic Sensing, Dalian Maritime University, Dalian 116026, China.
Yuejun KangSchool of Materials and Energy, Southwest University, Chongqing 400715, China.
Xinxiang PanCollege of Electronics and Information Engineering, Guangdong Ocean University, Zhanjiang 524088, China.
Dalian Maritime University · CNGuangdong Ocean University · CNSouthwest University · CN

Funding

Dalian science and technology innovation fund 2018J11CY021LiaoNing Revitalization Talents Program XLYC1807036National Key Research and Development Program of China 2017YFC1404603, 2017YFC1404606National Natural Science Foundation of China 51779027the Fundamental Research Funds for the Central Universities 3132019217, 3132018261
6 · The paper itself

Abstract

There are a huge number, and abundant types, of microalgae in the ocean; and most of them have various values in many fields, such as food, medicine, energy, feed, etc. Therefore, how to identify and separation of microalgae cells quickly and effectively is a prerequisite for the microalgae research and utilization. Herein, we propose a microfluidic system that comprised microalgae cell separation, treatment and viability characterization. Specifically, the microfluidic separation function is based on the principle of deterministic lateral displacement (DLD), which can separate various microalgae species rapidly by their different sizes. Moreover, a concentration gradient generator is designed in this system to automatically produce gradient concentrations of chemical reagents to optimize the chemical treatment of samples. Finally, a single photon counter was used to evaluate the viability of treated microalgae based on laser-induced fluorescence from the intracellular chlorophyll of microalgae. To the best of our knowledge, this is the first laboratory prototype system combining DLD separation, concentration gradient generator and chlorophyll fluorescence detection technology for fast analysis and treatment of microalgae using marine samples. This study may inspire other novel applications of micro-analytical devices for utilization of microalgae resources, marine ecological environment protection and ship ballast water management.

Indexed as

Cell SeparationCell SurvivalFluorescenceMicroalgaeMicrofluidicsMovementRheologySolutionsSolutionschlorophyll fluorescenceconcentration gradient generatordeterministic lateral displacementmicrofluidic chipsingle photon detection

Identifiers

PMID31766178
PMCPMC6891504
OpenAlexW2988127548

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked