Evidence map›Paper›PMID 31765375›Full record

ArticlePloS one2019

In-situ time resolved spectrographic measurement using an additively manufactured metallic micro-fluidic analysis platform.

T W Monaghan, M J Harding, S D R Christie, R J Friel

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 3 countries.

T W MonaghanMinistry of Defence Abbey Wood, Bristol, United Kingdom.
M J HardingSchool of Chemical and Bioprocess Engineering, University College Dublin, Dublin, Ireland.
S D R ChristieDepartment of Chemistry, Loughborough University, Loughborough, United Kingdom.
R J FrielSchool of Information Technology, Halmstad University, Halmstad, Sweden.ORCID 0000-0002-0480-4079
Halmstad University · SELoughborough University · GBMinistry of Defence · GBUniversity College Dublin · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionMicrofluidic reactionware allows small volumes of reagents to be utilized for highly controlled flow chemistry applications. By integrating these microreactors with onboard analytical systems, the devices change from passive ones to active ones, increasing their functionality and usefulness. A pressing application for these active microreactors is the monitoring of reaction progress and intermediaries with respect to time, shedding light on important information about these real-time synthetic processes.

objectiveIn this multi-disciplinary study the objective was to utilise advanced digital fabrication to research metallic, active microreactors with integrated fibre optics for reaction progress monitoring of solvent based liquids, incompatible with previously researched polymer devices, in combination with on-board Ultraviolet-visible spectroscopy for real-time reaction monitoring.

methodA solid-state, metal-based additive manufactured system (Ultrasonic Additive Manufacturing) combined with focussed ion beam milling, that permitted the accurate embedment of delicate sensory elements directly at the point of need within aluminium layers, was researched as a method to create active, metallic, flow reactors with on-board sensing. This outcome was then used to characterise and correctly identify concentrations of UV-active water-soluble B-vitamin nicotinamide and fluorescein. A dilution series was formed from 0.01-1.75 mM; which was pumped through the research device and monitored using UV-vis spectroscopy.

resultsThe results uniquely showed the in-situ ion milling of ultrasonically embedded optical fibres resulted in a metallic microfluidic reaction and monitoring device capable of measuring solvent solutions from 18 μM to 18 mM of nicotinamide and fluorescein, in real time. This level of accuracy highlights that the researched device and methods are capable of real-time spectrographic analysis of a range of chemical reactions outside of those possible with polymer devices.

Indexed as

AluminumChemistry Techniques, SyntheticMicrofluidic Analytical TechniquesOptical FibersSolventsSpectrum AnalysisTime FactorsUltrasonic WavesAluminumSolvents

Identifiers

PMID31765375
PMCPMC6876875
OpenAlexW2990483032

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.