Evidence map›Paper›PMID 31762832›Full record

ArticleJournal of cardiology cases2019

Delivery balloon rupture during transcatheter heart valve alignment procedure in extreme descending aorta tortuosity.

Yoji Sumimoto, Yukihiro Fukuda, Hiroki Ikenaga, Hitoshi Susawa, Ken Ishibashi, Satoshi Kurisu, Keijiro Katayama, Shinya Takahashi, Taijiro Sueda, Yasuki Kihara

Open access · bronzeAbstract readCase Reports
In one paragraph

Article in Journal of cardiology cases, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Yoji SumimotoDepartment of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Yukihiro FukudaDepartment of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Hiroki IkenagaDepartment of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Hitoshi SusawaDepartment of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Ken IshibashiDepartment of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Satoshi KurisuDepartment of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Keijiro KatayamaDepartment of Surgery, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Shinya TakahashiDepartment of Surgery, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Taijiro SuedaDepartment of Surgery, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Yasuki KiharaDepartment of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
Hiroshima University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A 79-year-old man with a history of partial resection of the lung and the bladder due to cancer, hypertension, dyslipidemia, and heart failure, underwent transcatheter aortic valve replacement with a SAPIEN 3 (S3) valve (Edwards Lifesciences, Irvine, CA, USA). Preprocedural examination showed a bicuspid aortic valve and severe calcification of the leaflets. Computed tomography showed great tortuosity of the descending aorta. A 29-mm S3 valve prosthesis was advanced into the aorta, but a high degree of resistance was encountered in the middle of the descending aorta. The prosthesis was advanced to the level of aortic valve and an attempt was made to deploy the valve. However, the valve balloon did not expand. A balloon rupture was suspected. The balloon catheter was pulled back into the eSheath (Edwards Lifesciences), and the catheter and eSheath were removed together. Rupture of the balloon was confirmed. A new eSheath and prosthesis were prepared, with delivery supported with a Lunderquist guidewire (Cook Medical, Bloomington, IN, USA). The valve alignment procedure was performed in a straighter portion of the descending aorta. The new 29-mm S3 valve was then successfully implanted. <

Indexed as

AlignmentBalloon ruptureTranscatheter aortic valve replacement

Identifiers

PMID31762832
PMCPMC6859537
OpenAlexW2972086695

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.