ArticleJournal of cardiology cases2019
Delivery balloon rupture during transcatheter heart valve alignment procedure in extreme descending aorta tortuosity.
Article in Journal of cardiology cases, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Balloon Rupture During Balloon-Expandable TAVR: Insights Into the Role of Calcium Distribution and Lesion Preparation From Two Cases.Journal of the Society for Cardiovascular Angiography & Interventions · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A 79-year-old man with a history of partial resection of the lung and the bladder due to cancer, hypertension, dyslipidemia, and heart failure, underwent transcatheter aortic valve replacement with a SAPIEN 3 (S3) valve (Edwards Lifesciences, Irvine, CA, USA). Preprocedural examination showed a bicuspid aortic valve and severe calcification of the leaflets. Computed tomography showed great tortuosity of the descending aorta. A 29-mm S3 valve prosthesis was advanced into the aorta, but a high degree of resistance was encountered in the middle of the descending aorta. The prosthesis was advanced to the level of aortic valve and an attempt was made to deploy the valve. However, the valve balloon did not expand. A balloon rupture was suspected. The balloon catheter was pulled back into the eSheath (Edwards Lifesciences), and the catheter and eSheath were removed together. Rupture of the balloon was confirmed. A new eSheath and prosthesis were prepared, with delivery supported with a Lunderquist guidewire (Cook Medical, Bloomington, IN, USA). The valve alignment procedure was performed in a straighter portion of the descending aorta. The new 29-mm S3 valve was then successfully implanted. <
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.