ArticleThe Brazilian journal of infectious diseases : an official publication of the Brazilian Society of Infectious Diseases

Development and validation of a simple and rapid way to generate low volume of plasma to be used in point-of-care HIV virus load technologies.

Isabelle Vasconcellos, Diana Mariani, Marcelo C V M de Azevedo, Orlando C Ferreira, Amilcar Tanuri

Registry-linked trialAbstract readValidation Study
In one paragraph

Article in The Brazilian journal of infectious diseases : an official publication of the Brazilian Society of Infectious Diseases. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05048472 (Implementation of Point of Care HIV Viral Load Monitoring to Improve Viral Load Suppression Among Children, Adolescents and Young People Living With HIV in East Africa), which is not on this map. Cited by 2 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05048472 nacompletednot on this map

Implementation of Point of Care HIV Viral Load Monitoring to Improve Viral Load Suppression Among Children, Adolescents and Young People Living With HIV in East Africa

TypeinterventionalSponsorMRC/UVRI and LSHTM Uganda Research UnitRan2022 to 2025Enrolled956ConditionsHIV, Viral Load, Point of Care MonitoringArmsAbbott HIV-1/2 VL Point of care Device
3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Isabelle VasconcellosUniversidade Federal do estado do Rio de Janeiro, Hospital Universitário Gaffrèe e Guinle, Laboratório de Pesquisa em Imunologia e AIDS, Rio de Janeiro, RJ, Brazil.
Diana MarianiUniversidade Federal do Rio de Janeiro, Departamento de Genética-Instituto de Biologia, Rio de Janeiro, RJ, Brazil.
Marcelo C V M de AzevedoUniversidade Federal do estado do Rio de Janeiro, Hospital Universitário Gaffrèe e Guinle, Laboratório de Pesquisa em Imunologia e AIDS, Rio de Janeiro, RJ, Brazil.
Orlando C FerreiraUniversidade Federal do Rio de Janeiro, Departamento de Genética-Instituto de Biologia, Rio de Janeiro, RJ, Brazil.
Amilcar TanuriUniversidade Federal do Rio de Janeiro, Departamento de Genética-Instituto de Biologia, Rio de Janeiro, RJ, Brazil. Electronic address: atanuri@biologia.ufrj.br.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A new point-of-care HIV viral load, mPIMA HIV-1/2 VL, Abbott, USA, has been recently developed. This point-of-care viral load requires no skilled person to run and uses a small plasma volume (50μL). However, obtaining 50μL of plasma can be a challenge in limited resource settings. We validated a simple and easy method to obtain enough amount of plasma to run a point-of-care viral load. The study utilized 149 specimens from patients failing antiretroviral therapy. At least 250μL of whole blood was collected in a microtube/EDTA from fingerstick (fs-plasma) and immediately centrifuged. Parallel collection of venous blood to obtain plasma (vp-plasma) was used to compare performance in a point-of-care viral load assay and in methodology used in centralized laboratories Abbott M2000, Abbott, USA. The procedure for plasma collection takes less than 10min and in 94% of the cases only one fingerstick was sufficient to collect at least 250μL of blood. The Pearson correlation coefficient value for vp-plasma versus fs-plasma ran on mPIMA was 0.990. The Bland-Altman mean difference (md) for this comparison were virtually zero (md=-0.001) with limits of agreement between -0.225 and 0.223. In addition, the Pearson correlation coefficient value for fs-plasma in mPIMA versus vp-plasma in Abbott M2000 was 0.948 for values above the mPIMA limit of quantification (LoQ; from 800 to 1,000,000copies/mL). These results validate this simple plasma isolation method capable to be implemented in low resource countries where point-of-care decentralization is deeply needed.

Indexed as

Point-of-Care SystemsFeasibility StudiesHIVHIV InfectionsHumansLinear ModelsPlasmaReproducibility of ResultsViral LoadFingerstick-plasmaHIVHIV viral loadmPIMAPOC VLPoint-of-care

Identifiers

PMID31760036
PMCPMC9392034

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.