Patient characteristics affecting accurate detection of sleep apnea using a bed sheet-type portable monitor.

Seiko Miyata, Hironao Otake, Motoo Ando, Masato Okuda, Hiroshige Fujishiro, Kunihiro Iwamoto, Akiko Noda, Michihiko Sone, Norio Ozaki

Abstract read
PubMed Publisher
In one paragraph

Article in Sleep & breathing = Schlaf & Atmung, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Seiko MiyataDepartment of Psychiatry, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan. s-miyata@med.nagoya-u.ac.jp.ORCID http://orcid.org/0000-0002-1144-5676
Hironao OtakeDepartment of Otorhinolaryngology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Motoo AndoDepartment of Clinical Laboratory, Nagoya University Hospital, Nagoya, Japan.
Masato OkudaDepartment of Biomedicial Sciences, Chubu University Graduate School of Life and Health Sciences, Kasugai, Japan.
Hiroshige FujishiroDepartment of Psychiatry, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan.
Kunihiro IwamotoDepartment of Psychiatry, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan.
Akiko NodaDepartment of Biomedicial Sciences, Chubu University Graduate School of Life and Health Sciences, Kasugai, Japan.
Michihiko SoneDepartment of Otorhinolaryngology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Norio OzakiDepartment of Psychiatry, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan.

Funding

Japan Society for the Promotion of Science 16K16600
6 · The paper itself

Abstract

purposeAlthough performed inside a laboratory, attended polysomnography (PSG) has long been the gold standard for the diagnosis of sleep apnea. However, high costs and long wait times have led to the development of home-based portable monitoring devices. A bed sheet-shaped device called SD102 (Suzuken Co., Nagoya, Japan) has been developed, and its accuracy in evaluating sleep apnea is becoming evident. The purpose of this study was to confirm the accuracy of SD102 in evaluating sleep apnea and to investigate patient characteristics that may contribute to inaccurate test results in patients with suspected obstructive sleep apnea (OSA).

methodsOne hundred and eighty-nine patients simultaneously underwent PSG and portable monitoring by using a home sleep apnea testing (HSAT) device. A blinded, experienced technologist using the American Academy of Sleep Medicine criteria versions 2.1 and 2.3 scored the PSG data and HSAT device data, respectively.

resultsThe respiratory event index (REI) by HSAT significantly correlated with the apnea-hypopnea index (AHI) by PSG (r = 0.974, p < 0.001). HSAT sensitivity, specificity, and positive and negative predictive values of 0.99, 0.83, 0.95, and 0.97, respectively. Body mass index and arousal index were significantly associated with the difference between REI from SD102 HSAT and AHI from PSG.

conclusionsThis study demonstrates the good agreement between REI and AHI in patients with suspected OSA and suggests that understanding the limitations of different testing methods may help in the accurate detection of OSA.