ArticleScientific reports2019
Functionalized Graphene Quantum Dot Interfaced Electrochemical Detection of Cardiac Troponin I: An Antibody Free Approach.
Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 59 citations in OpenAlex.
- Precursor-dependent optical and structural properties of eleven NIR-emissive graphene quantum dots for bioimaging applications.2d materials · 2026Article
- Quantum dot enhanced photonic biosensors for single cell analysis from synthesis to clinical application.Discover nano · 2026Review
- Research progress on nanomaterial-empowered electrochemical biosensors for the detection of cardiac troponin I.RSC advances · 2025Review
- Recent Advances in Monitoring Technologies for Cardiac Troponin I: A Pivotal Biomarker in Cardiovascular Diseases.Biomolecules · 2025Review
- Review
- Advances in nanotechnological approaches for the detection of early markers associated with severe cardiac ailments.Nanomedicine (London, England) · 2024Review
- Synthesis of highly fluorescent carbon quantum dots from rubber seed shells for the adsorption and photocatalytic degradation of dyes.Scientific reports · 2023Article
- Label-Free Immunosensor Based on Liquid Crystal and Gold Nanoparticles for Cardiac Troponin I Detection.Biosensors · 2022Article
- Review
- Electroanalytical point-of-care detection of gold standard and emerging cardiac biomarkers for stratification and monitoring in intensive care medicine - a review.Mikrochimica acta · 2022Review
- Graphene Quantum Dots-Based Electrochemical Biosensing Platform for Early Detection of Acute Myocardial Infarction.Biosensors · 2022Article
- Fabrication of GQD-Electrodeposited Screen-Printed Carbon Electrodes for the Detection of the CRP Biomarker.ACS omega · 2021Article
- Cyclodextrin-modified graphene quantum dots as a novel additive for the selective separation of bioactive compounds by capillary electrophoresis.Mikrochimica acta · 2021Article
- Do amino acid functionalization stratagems on carbonaceous quantum dots imply multiple applications? A comprehensive review.RSC advances · 2021Review
- Carbon nanomaterials for cardiovascular theranostics: Promises and challenges.Bioactive materials · 2021Review
- Sensitive impedimetric detection of troponin I with metal-organic framework composite electrode.RSC advances · 2021Article
- Applications of Graphene Quantum Dots in Biomedical Sensors.Sensors (Basel, Switzerland) · 2020Review
- Nanoscale Technologies in Highly Sensitive Diagnosis of Cardiovascular Diseases.Frontiers in bioengineering and biotechnology · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
According to the World Health Organization (WHO), cardiovascular disease (CVD) is the leading cause of death in the world every year. The design and development of biosensors for the detection of CVD markers could be one of the major contributions of the scientific community to society. In this context, acetic acid functionalized graphene quantum dots (fGQDs) were used as an interface for the electrochemical detection of cardiac Troponin I (cTnI). The interaction of cTnI with fGQDs for the early diagnosis of acute myocardial infarction was investigated using cyclic voltammetry (CV) and amperometry. The carbodiimide conjugation between the N-H group of cTnI and the functionalized COOH group on GQDs enabled the detection of cTnI biomarker. The same sensing mechanism was confirmed using Fourier Transform Infrared Spectrometry (FTIR). The fGQDs modified Au electrode showed remarkable electrocatalytic oxidation of cTnI with good stability and sensitivity over a linear range of 0.17 to 3 ng mL
Indexed as
Identifiers
What OpenQuestion holds
Registered trials