Respiratory motion-corrected, compressively sampled dynamic MR image reconstruction by exploiting multiple sparsity constraints and phase correlation-based data binning.
Article in Magma (New York, N.Y.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Deep Learning Assisted Outer Volume Removal for Highly-Accelerated Real-Time Dynamic MRI.ArXiv · 2025Article
- Cardiac MR image reconstruction using cascaded hybrid dual domain deep learning framework.PloS one · 2025Article
- SC-GROG followed by L+S reconstruction with multiple sparsity constraints for accelerated Golden-angle-radial DCE-MRI.PloS one · 2025Article
- ROBUST OUTER VOLUME SUBTRACTION WITH DEEP LEARNING GHOSTING DETECTION FOR HIGHLY-ACCELERATED REAL-TIME DYNAMIC MRI.Proceedings. IEEE International Symposium on Biomedical Imaging · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionCardiac magnetic resonance imaging (cMRI) is a standard method that is clinically used to evaluate the function of the human heart. Respiratory motion during a cMRI scan causes blurring artefacts in the reconstructed images. In conventional MRI, breath holding is used to avoid respiratory motion artefacts, which may be difficult for cardiac patients. MATERIALS AND
methodsThis paper proposes a method in which phase correlation-based binning, followed by image registration-based sparsity along with spatio-temporal sparsity, is incorporated into the standard low rank + sparse (L+S) reconstruction for free-breathing cardiac cine MRI. The proposed method is validated on clinical data and simulated free-breathing cardiac cine data for different acceleration factors (AFs). The reconstructed images are analysed using visual assessment, artefact power (AP) and root-mean-square error (RMSE). The results of the proposed method are compared with the contemporary motion-corrected compressed sensing (MC-CS) method given in the literature.
resultsOur results show that the proposed method successfully reconstructs the motion-corrected images from respiratory motion-corrupted, compressively sampled cardiac cine MR data, e.g., there is 26% and 24% improvement in terms of AP and RMSE values, respectively, at AF = 4 and 20% and 16.04% improvement in terms of AP and RMSE values, respectively, at AF = 8 in the reconstruction results from the proposed method for the cardiac phantom cine data.
conclusionThe proposed method achieves significant improvement in the AP and RMSE values at different AFs for both the phantom and in vivo data.
Indexed as