Evidence map›Paper›PMID 31752875›Full record

ArticleBMC ophthalmology2019

A modified intrascleral intraocular lens fixation technique with fewer anterior segment manipulations: 27-gauge needle-guided procedure with built-in 8-0 absorbable sutures.

Yuan Yang, Teng-Teng Yao, Ya-Li Zhou, Yi-Xiao Wang, Zhao-Yang Wang

Open access · goldAbstract read
In one paragraph

Article in BMC ophthalmology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Long-Term Stability of Intraocular Lens with Trimmed or Untrimmed Haptics in Yamane Sutureless Intrascleral Fixation Technique.Medical science monitor : international medical journal of experimental and clinical research · 2021
    Article
  5. Article
  6. Sutureless Scleral Fixated IOL: The "Catcher Pole" Technique.Clinical ophthalmology (Auckland, N.Z.) · 2021
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Yuan YangDepartment of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, No. 639 Zhizaoju Road, Shanghai, 200011, China.
Teng-Teng YaoDepartment of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, No. 639 Zhizaoju Road, Shanghai, 200011, China.
Ya-Li ZhouDepartment of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, No. 639 Zhizaoju Road, Shanghai, 200011, China.
Yi-Xiao WangDepartment of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, No. 639 Zhizaoju Road, Shanghai, 200011, China.
Zhao-Yang WangDepartment of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, No. 639 Zhizaoju Road, Shanghai, 200011, China. zhaokekewzy@hotmail.com.ORCID http://orcid.org/0000-0002-3124-7060
Shanghai Jiao Tong University · CN

Funding

Clinical Research Promotion Program of Ninth People's Hospital Affiliated to Medical College of Shanghai Jiao Tong University JYLJ032Shanghai Municipal Education Commission- Gaofeng Clinical Medicine Grant Support 20181810Shanghai Smart Medical Special Research Project 2018ZHYL0221the National Key R&D Program of China 2018YFC1106100, 2018YFC1106101the National Natural Science Foundation of China 81770934the Science and Technology Commission of Shanghai 17DZ2260100
6 · The paper itself

Abstract

backgroundTo report a modified surgical technique for intrascleral intraocular lens (IOL) fixation with fewer anterior segment manipulations in eyes lacking sufficient capsular support.

methodsEyes from 14 patients who underwent 27-gauge needle-guided intrascleral IOL fixation with built-in 8-0 absorbable sutures were studied. The 8-0 absorbable sutures were inserted into 27-gauge round needles and used to create sclerotomies at the 4 o'clock and 10 o'clock positions under the scleral flap. The sutures were used to tie knots at the end of each haptic and guide haptic externalization through the sclerotomy. After externalization, a sufficient flange was created at the end of each haptic and fixed under the scleral flaps. The best corrected visual acuity (BCVA), corneal endothelial cell density (ECD), IOL tilt and decentration, previous surgery history, and complications were determined.

resultsFourteen cases were analyzed. The majority of eyes exhibited an improvement in the BCVA after surgery. When comparing the last follow-up to preoperative visual acuity, the mean change in BCVA was + 26.32 letters (p = 0.011). Postoperative complications included postoperative hypotony in 3 eyes, ocular hypertension in 2 eyes. No cases of postoperative cystoid macular edema (CME), vitreous hemorrhage (VH), IOL dislocation, or endophthalmitis were observed.

conclusionsThe 27-gauge needle-guided intrascleral IOL fixation technique with built-in 8-0 absorbable sutures is easy to perform with fewer anterior chamber manipulations and achieves both anatomical and optical stability.

Indexed as

Suture TechniquesAdolescentAdultAgedAnterior Eye SegmentAphakia, PostcataractChildFemaleHumansLenses, IntraocularLens Implantation, IntraocularMaleMiddle AgedPostoperative ComplicationsRetrospective StudiesSclera27-gauge round needle8–0 absorbable sutureFlangeIntrascleral intraocular lens fixation

Identifiers

PMID31752875
PMCPMC6873762
OpenAlexW2991403267

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.