ArticleMagnetic resonance in medicine2020
In vivo human head MRI at 10.5T: A radiofrequency safety study and preliminary imaging results.
Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 49 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
49 citing papers in PubMed.
- SAR validation of RF coils and implants in a B0-free RF safety laboratory.Medical physics · 2026Article
- Mesoscale Whole-Brain TMagnetic resonance in medicine · 2026Article
- A Numerical Alternative to MR Thermometry for Safety Validation of Multi-Channel RF Transmit Coils.Magnetic resonance in medicine · 2026Article
- BOLD fMRI at 9.4T with 3D stack-of-spirals readouts.Magma (New York, N.Y.) · 2026Article
- Advancing whole-brain BOLD functional MRI in humans at 10.5 T with motion-robust 3D echo-planar imaging, parallel transmission, and high-density radiofrequency receive coils.Magnetic resonance in medicine · 2026Article
- A unipolar head gradient for high-field MRI without encoding ambiguity.Magnetic resonance in medicine · 2026Article
- A Coupled Multimodal Planar Transmit RF Array for Ultrahigh Field Spine MR Imaging.IEEE transactions on bio-medical engineering · 2026Article
- On the RF safety of titanium mesh head implants in 7 T MRI systems: an investigation.Magnetic resonance in medicine · 2025Article
- A 128-channel receive array with enhanced signal-to-noise ratio performance for 10.5T brain imaging.Magnetic resonance in medicine · 2025Article
- 500 MHz Inductive Birdcage RF Coil for Brain MRI: Design, Implementation and Validation.IEEE transactions on bio-medical engineering · 2025Article
- Reproducibility of Electromagnetic Field Simulations of Local Radiofrequency Transmit Elements Tailored for 7 T MRI.Sensors (Basel, Switzerland) · 2025Article
- RF coil design strategies for improving SNR at the ultrahigh magnetic field of 10.5T.Magnetic resonance in medicine · 2025Article
- Radiofrequency Enhancer to Recover Signal Dropouts in 7 Tesla Diffusion MRI.Sensors (Basel, Switzerland) · 2024Article
- A Quantitative Comparison ofSensors (Basel, Switzerland) · 2024Article
- Performance of receive head arrays versus ultimate intrinsic SNR at 7 T and 10.5 T.Magnetic resonance in medicine · 2024Article
- Simulation Validation of an 8-Channel Parallel-Transmit Dipole Array on an Infant Phantom: Including RF Losses for Robust Correlation with Experimental Results.Sensors (Basel, Switzerland) · 2024Article
- Changes in tissue sodium concentration and sodium relaxation times during the maturation of human knee cartilage: Ex vivoMagnetic resonance in medicine · 2024Article
- Implant-friendly MRI of deep brain stimulation electrodes at 7 T.Magnetic resonance in medicine · 2023Article
- A 32-Channel Sleeve Antenna Receiver Array for Human Head MRI Applications at 10.5 T.IEEE transactions on medical imaging · 2023Article
- Super-resolution reconstruction in ultrahigh-field MRI.Biophysical reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
purposeThe purpose of this study is to safely acquire the first human head images at 10.5T.
methodsTo ensure safety of subjects, we validated the electromagnetic simulation model of our coil. We obtained quantitative agreement between simulated and experimental
resultsQuantitative agreement between the simulated and experimental results was obtained including S-parameters,
conclusionsIn this study, we acquired the first in vivo human head images at 10.5T using an 8-channel transmit/receive coil. We implemented and expanded a previously proposed workflow to validate the electromagnetic simulation model of the 8-channel transmit/receive coil. Using the validated coil model, we calculated radiofrequency power levels to safely image human subjects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.