Evidence map›Paper›PMID 31751234›Full record

ArticleIEEE transactions on medical imaging2020

4D Flow MRI Pressure Estimation Using Velocity Measurement-Error-Based Weighted Least-Squares.

Jiacheng Zhang, Melissa C Brindise, Sean Rothenberger, Susanne Schnell, Michael Markl, David Saloner, Vitaliy L Rayz, Pavlos P Vlachos

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Modeling Bias Error in 4D Flow MRI Velocity Measurements.IEEE transactions on medical imaging · 2022
    Article
  12. On the numerical treatment of viscous and convective effects in relative pressure reconstruction methods.International journal for numerical methods in biomedical engineering · 2022
    Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Jiacheng Zhang
Melissa C Brindise
Sean Rothenberger
Susanne Schnell
Michael Markl
David Saloner
Vitaliy L Rayz
Pavlos P Vlachos
Purdue University West Lafayette · USNorthwestern University · USUniversity of California, San Francisco · US

Funding

Multi-modality 4D Flow MRI data enhancement for quantification of cerebral aneurysms hemodynamicsR21NS106696 · NINDS · PURDUE UNIVERSITY · PI RAYZ, VITALIY L, SCHNELL, SUSANNE · 2018 to 2019
$419k
NINDS NIH HHS R21 NS106696
6 · The paper itself

Abstract

This work introduces a 4D flow magnetic resonance imaging (MRI) pressure reconstruction method which employs weighted least-squares (WLS) for pressure integration. Pressure gradients are calculated from the velocity fields, and velocity errors are estimated from the velocity divergence for incompressible flow. Pressure gradient errors are estimated by propagating the velocity errors through Navier-Stokes momentum equation. A weight matrix is generated based on the pressure gradient errors, then employed for pressure reconstruction. The pressure reconstruction method was demonstrated and analyzed using synthetic velocity fields as well as Poiseuille flow measured using in vitro 4D flow MRI. Performance of the proposed WLS method was compared to the method of solving the pressure Poisson equation which has been the primary method used in the previous studies. Error analysis indicated that the proposed method is more robust to velocity measurement errors. Improvement on pressure results was found to be more significant for the cases with spatially-varying velocity error level, with reductions in error ranging from 50% to over 200%. Finally, the method was applied to flow in patient-specific cerebral aneurysms. Validation was performed with in vitro flow data collected using Particle Tracking Velocimetry (PTV) and in vivo flow measurement obtained using 4D flow MRI. Pressure calculated by WLS, as opposed to the Poisson equation, was more consistent with the flow structures and showed better agreement between the in vivo and in vitro data. These results suggest the utility of WLS method to obtain reliable pressure field from clinical flow measurement data.

Indexed as

AlgorithmsMagnetic Resonance ImagingBlood Flow VelocityHumansLeast-Squares AnalysisMotionReproducibility of Results

Identifiers

PMID31751234
PMCPMC10359051
OpenAlexW2989662290

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.