ArticleScientific reports2019
Fabrication and characterization of AlN-based flexible piezoelectric pressure sensor integrated into an implantable artificial pancreas.
Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 56 citations in OpenAlex.
- Multiplexed catheter-integrated pressure sensing system for endoluminal interventions.Microsystems & nanoengineering · 2026Article
- Enhanced high-temperature thermoelectric performance in 1D AlN nanotubes: a comparative dimensionality analysis.Journal of molecular modeling · 2026Article
- Advancements in Biomedical Sensors for Early Detection of Failure in Hip and Knee Implants: Scoping Review on Potential Sensors for Implant Integration.Annals of biomedical engineering · 2025Article
- A soft thermal sensor for the continuous assessment of flow in vascular access.Nature communications · 2025Article
- Recent Progress and Challenges of Implantable Biodegradable Biosensors.Micromachines · 2024Review
- Aluminum Nitride Thin Film Piezoelectric Pressure Sensor for Respiratory Rate Detection.Sensors (Basel, Switzerland) · 2024Article
- Rational Design of Flexible Mechanical Force Sensors for Healthcare and Diagnosis.Materials (Basel, Switzerland) · 2023Review
- Flexible and Stretchable Pressure Sensors: From Basic Principles to State-of-the-Art Applications.Micromachines · 2023Review
- Doping Engineering for Optimizing Piezoelectric and Elastic Performance of AlN.Materials (Basel, Switzerland) · 2023Article
- A Strategy for Extracting Full Material Coefficients of AlN Thin Film Based on Resonance Method.Micromachines · 2022Article
- Fabry-Perot Pressure Sensors Based on Polycrystalline Diamond Membranes.Materials (Basel, Switzerland) · 2021Article
- Modeling, Fabrication and Integration of Wearable Smart Sensors in a Monitoring Platform for Diabetic Patients.Sensors (Basel, Switzerland) · 2021Article
- Locally Controlled Sensing Properties of Stretchable Pressure Sensors Enabled by Micro-Patterned Piezoresistive Device Architecture.Sensors (Basel, Switzerland) · 2020Article
- Nanoarchitectonics for Wide Bandgap Semiconductor Nanowires: Toward the Next Generation of Nanoelectromechanical Systems for Environmental Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2020Review
- Miniaturized Piezo Force Sensor for a Medical Catheter and Implantable Device.ACS applied electronic materials · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study reports on the fabrication and characterization of an event detection subsystem composed of a flexible piezoelectric pressure sensor and the electronic interface to be integrated into an implantable artificial pancreas (IAP) for diabetic patients. The developed sensor is made of an AlN layer, sandwiched between two Ti electrodes, sputtered on Kapton substrate, with a preferential orientation along c-axis which guarantees the best piezoelectric response. The IAP is made of an intestinal wall-interfaced refilling module, able to dock an ingestible insulin capsule. A linearly actuated needle punches the duodenum tissue and then the PDMS capsule to transfer the insulin to an implanted reservoir. The device is located at the connection of the needle with the linear actuator to reliably detect the occurred punching of the insulin-filled capsule. Finite Element Analysis (FEA) simulations were performed to evaluate the piezoelectric charge generated for increasing loads in the range of interest, applied on both the sensor full-area and footprint area of the Hamilton needle used for the capsule punching. The sensor-interface circuit was simulated to estimate the output voltage that can be obtained in real operating conditions. The characterization results confirmed a high device sensitivity during the punching, in the low forces (0-4 N) and low actuator speed (2-3 mm/s) ranges of interest, meeting the requirement of the research objective. The choice of a piezoelectric pressure sensor is particularly strategic in the medical field due to the request of self-powered implantable devices which do not need any external power source to output a signal and harvest energy from natural sources around the patient.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.