Evidence map›Paper›PMID 31746055›Full record

ArticleMagnetic resonance in medicine2020

Simultaneous multislice imaging of the heart using multiband balanced SSFP with blipped-CAIPI.

Anthony N Price, Lucilio Cordero-Grande, Shaihan J Malik, Joseph V Hajnal

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Simultaneous multi-slice cardiac real-time MRI at 0.55T.Magnetic resonance in medicine · 2025
    Article
  3. Article
  4. Clinical utility of a rapid two-dimensional balanced steady-state free precession sequence with deep learning reconstruction.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Article
  5. Simultaneous multislice cardiac multimapping based on locally low-rank and sparsity constraints.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Anthony N PriceSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.ORCID 0000-0002-6907-7554
Lucilio Cordero-GrandeSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.ORCID 0000-0003-1477-304X
Shaihan J MalikSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.ORCID 0000-0001-8925-9032
Joseph V HajnalSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.

Funding

Department of HealthMedical Research Council MR/K006355/1Wellcome TrustWellcome Trust WT 203148/Z/16/Z
6 · The paper itself

Abstract

purposeIn this work, we explore the use of multiband (MB) balanced steady-state free precession (bSSFP) with blipped-controlled aliasing in parallel imaging (CAIPI), which avoids the issues of altered frequency response associated with RF phase cycling, and show its application to accelerating cardiac cine imaging.

methodsBlipped and RF-cycled CAIPI were implemented into a retrospective-gated segmented cine multiband bSSFP sequence. The 2 methods were compared at 3T using MB2 to demonstrate the effect on frequency response. Further data (4 subjects) were acquired at both 1.5T and 3T collecting 12-slice short axis stacks using blipped-CAIPI with MB acceleration factors of 1-4. The impact on SNR and contrast was evaluated along with g-factors at different accelerations.

resultsData acquired with blipped-CAIPI multiband bSSFP up to factor 4 yielded functional cine data with good SNR and contrast, while reliably keeping dark-band artefacts clear of the heart at 1.5T. SAR limits the maximum MB acceleration, particularly at 3T, where minimum TR increase is problematic and leakage artefacts are more prevalent. Mean g-factors across the heart were measured at 1.00, 1.06, and 1.12 for MB2-MB4, whereas blood-pool SNR measures (end-diastole) decreased by 11.8, 21.5, and 36.9%; ultimately LV-myocardium CNR remained sufficient at 1.5T with values ranging: 15.6, 13.4, 11.9, and 9.6 (MB1-MB4).

conclusionBlipped-CAIPI multiband bSSFP can be used in cardiovascular applications without affecting the frequency response because of controlled aliasing and can be readily incorporated into segmented cine acquisitions without adding any additional constraints because of phase cycling requirements. The method was used to collect full ventricular coverage within a single breath-hold.

Indexed as

HeartImage Interpretation, Computer-AssistedHeart VentriclesHumansMagnetic Resonance Imaging, CineReproducibility of ResultsRetrospective Studiesbalanced SSFPbanding artefactsblipped-CAIPIcine CMRmultibandsimultaneous multislice

Identifiers

PMID31746055
PMCPMC7065016

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.