ArticleMagnetic resonance in medicine2020
Simultaneous multislice imaging of the heart using multiband balanced SSFP with blipped-CAIPI.
Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Efficient Interleaved Multi-Band Outer Volume Suppression for Highly Accelerated Simultaneous Multi-Slice Imaging of the Heart.Bioengineering (Basel, Switzerland) · 2026Article
- Simultaneous multi-slice cardiac real-time MRI at 0.55T.Magnetic resonance in medicine · 2025Article
- Qualitative and Quantitative Evaluation of a Deep Learning-Based Reconstruction for Accelerated Cardiac Cine Imaging.Bioengineering (Basel, Switzerland) · 2025Article
- Clinical utility of a rapid two-dimensional balanced steady-state free precession sequence with deep learning reconstruction.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024Article
- Simultaneous multislice cardiac multimapping based on locally low-rank and sparsity constraints.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024Article
- Contrast-optimal simultaneous multi-slice bSSFP cine cardiac imaging at 0.55 T.Magnetic resonance in medicine · 2023Article
- Simultaneous multislice steady-state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T.Magnetic resonance in medicine · 2022Article
- All-systolic first-pass myocardial rest perfusion at a long saturation time using simultaneous multi-slice imaging and compressed sensing acceleration.Magnetic resonance in medicine · 2021Article
- Improved simultaneous multislice cardiac MRI using readout concatenated k-space SPIRiT (ROCK-SPIRiT).Magnetic resonance in medicine · 2021Article
- Combined simultaneous multislice bSSFP and compressed sensing for first-pass myocardial perfusion at 1.5 T with high spatial resolution and coverage.Magnetic resonance in medicine · 2020Article
- Simultaneous multislice imaging of the heart using multiband balanced SSFP with blipped-CAIPI.Magnetic resonance in medicine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeIn this work, we explore the use of multiband (MB) balanced steady-state free precession (bSSFP) with blipped-controlled aliasing in parallel imaging (CAIPI), which avoids the issues of altered frequency response associated with RF phase cycling, and show its application to accelerating cardiac cine imaging.
methodsBlipped and RF-cycled CAIPI were implemented into a retrospective-gated segmented cine multiband bSSFP sequence. The 2 methods were compared at 3T using MB2 to demonstrate the effect on frequency response. Further data (4 subjects) were acquired at both 1.5T and 3T collecting 12-slice short axis stacks using blipped-CAIPI with MB acceleration factors of 1-4. The impact on SNR and contrast was evaluated along with g-factors at different accelerations.
resultsData acquired with blipped-CAIPI multiband bSSFP up to factor 4 yielded functional cine data with good SNR and contrast, while reliably keeping dark-band artefacts clear of the heart at 1.5T. SAR limits the maximum MB acceleration, particularly at 3T, where minimum TR increase is problematic and leakage artefacts are more prevalent. Mean g-factors across the heart were measured at 1.00, 1.06, and 1.12 for MB2-MB4, whereas blood-pool SNR measures (end-diastole) decreased by 11.8, 21.5, and 36.9%; ultimately LV-myocardium CNR remained sufficient at 1.5T with values ranging: 15.6, 13.4, 11.9, and 9.6 (MB1-MB4).
conclusionBlipped-CAIPI multiband bSSFP can be used in cardiovascular applications without affecting the frequency response because of controlled aliasing and can be readily incorporated into segmented cine acquisitions without adding any additional constraints because of phase cycling requirements. The method was used to collect full ventricular coverage within a single breath-hold.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.