Evidence map›Paper›PMID 31741288›Full record

ArticleMedical & biological engineering & computing2020

Experimental validation of adaptive pedicle screws-a novel implant concept using shape memory alloys.

Michael Werner, Niels Hammer, Christian Rotsch, Isabell Berthold, Mario Leimert

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 17 citations in OpenAlex.

  1. A comprehensive review of biomechanical factors influencing pedicle screw fixation strength and the critical role of artificial intelligence.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Michael WernerDepartment of Medical Engineering, Fraunhofer Institute for Machine Tools and Forming Technology IWU, Nöthnitzer Straße 44, 01187, Dresden, Germany. michael.werner@iwu.fraunhofer.de.ORCID http://orcid.org/0000-0002-7864-9446
Niels HammerDepartment of Medical Engineering, Fraunhofer Institute for Machine Tools and Forming Technology IWU, Nöthnitzer Straße 44, 01187, Dresden, Germany.
Christian RotschDepartment of Medical Engineering, Fraunhofer Institute for Machine Tools and Forming Technology IWU, Nöthnitzer Straße 44, 01187, Dresden, Germany.
Isabell BertholdDepartment of Medical Engineering, Fraunhofer Institute for Machine Tools and Forming Technology IWU, Nöthnitzer Straße 44, 01187, Dresden, Germany.
Mario LeimertDepartment of Neurosurgery and Spine Surgery, Sächsische Schweiz Klinik Sebnitz, Senftenberg, Germany.
Fraunhofer Institute for Machine Tools and Forming Technology · DEMedical University of Graz · AT

Funding

Saxony Ministry for Science and Arts 4-7531.50-02-876-10/1
6 · The paper itself

Abstract

Pedicle screw fixation is a standard procedure in spine surgery. A secure anchoring in deficient (e.g., osteoporotic) bone or in a secondary supply after a revision is a major challenge. This study aimed to test the primary stability of a new self-expanding shape memory actuator screw concept with the traditional screw design. The actuator part braces itself against the osseous environment after implantation by heating to body temperature. Thirty screws and twenty-four actuator sheets were manufactured and tested in vertebrae from seven human cadavers in vitro. The pullout force and mechanical work for the pullout were evaluated. Bone quality was determined from μCT. The mean actuator sheet compression force of the used shape memory alloy (SMA) sheets averaged - 8.2 ± 0.6 N. Seven of the SMA screws activated correctly after the implantation, four activated unilaterally only. The pullout force averaged 868 ± 392 N for the standard screws and 828 ± 353 N for the SMA screws. The mechanical work was conducted after the first 100 N, and the loss of strain resistance of 40% of the pullout force averaged 2.2 ± 1.6 Nm for the standard screws, and 1.7 ± 0.9 Nm for the SMA screws. Consequently, the novel concept showed non-inferiority compared with the traditional screw designs. Graphical abstract.

Indexed as

Pedicle ScrewsProstheses and ImplantsAgedAged, 80 and overBiomechanical PhenomenaBone and BonesCadaverComputer SimulationFemaleFinite Element AnalysisHot TemperatureHumansMaleShape Memory AlloysShape Memory AlloysExpandable implantMechanical strengthPedicle screwShape memory alloy

Identifiers

PMID31741288
OpenAlexW2987510751

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked