Trial reportLasers in medical science2020
Comparison of navigated laser and conventional single-spot laser system for induced pain during panretinal photocoagulation.
Trial report in Lasers in medical science, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Comparison of Pain Scores Among Patients Undergoing Conventional and Novel Panretinal Photocoagulation for Diabetic Retinopathy: A Systematic Review.Clinical ophthalmology (Auckland, N.Z.) · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To compare the panretinal photocoagulation (PRP)-induced pain response between novel navigated laser (Navilas) and conventional single-spot laser. The eyes were randomly assigned to Navilas or conventional laser. Contralateral eyes underwent PRP with the other system with 30 min resting interval. Pulse duration was 100 ms in conventional laser and 30 ms or 100 ms in Navilas and power setting was enough to create gray-white light burn on both devices. Pain response was evaluated by verbal scale (VS) (0-4) and visual analog scale (VAS) (0-10) after each PRP application. The mean age of 70 patients (140 eyes) was 62.52 ± 9.49 years. Mean power and spot numbers for Navilas and conventional laser were 291.9 ± 85.3 mW vs 368.4 ± 72.0 mW, and 375.4 ± 108.4 vs 374.2 ± 105.0 (p < 0.001 and p = 0.53, respectively). Pain scores for Navilas and conventional laser were 1.19 ± 0.73 and 1.99 ± 0.84 for VS and 2.41 ± 1.65 and 4.74 ± 2.17 for VAS (p < 0.001 and p < 0.001). More comfortable PRP is achieved with Navilas system in comparison with conventional single-spot laser system. However, small number of patients treated with same pulse duration and different contact lenses used for two systems should be taken into consideration. Besides, we did not report comparative clinical efficiency of either laser system.
Indexed as
Identifiers
31741148What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.