Observational studyThe journal of trauma and acute care surgery2020
A comparison between the TEG 6s and TEG 5000 analyzers to assess coagulation in trauma patients.
Observational study in The journal of trauma and acute care surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
32 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- The European guideline on management of major bleeding and coagulopathy following trauma: sixth edition.Critical care (London, England) · 2023Guideline
- Thromboelastography-Guided Therapy Enhances Patient Blood Management in Cirrhotic Patients: A Meta-analysis Based on Randomized Controlled Trials.Seminars in thrombosis and hemostasis · 2023Pooled it
- Initial TEG 6s parameters for risk stratification of hemorrhage-related outcomes in massively transfused trauma patients.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Precision hemostasis: how viscoelastic testing guides real-time decision-making in trauma.Trauma surgery & acute care open · 2026Review
- Viscoelastic Hemostatic Assays in the Management of Trauma-Induced Coagulopathy: A Clinical Update.Journal of clinical medicine · 2025Review
- Article
- Predictive accuracy of diagnostic tests for excessive bleeding in cardiac surgery: The COPTIC-C study.Transfusion · 2025Article
- The impact of the patient's plasma volume on the amount of fresh frozen plasma needed to normalize the thromboelastographic reaction time.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025Article
- Discrepancy Between Conventional Coagulation Tests and Thromboelastography During the Early Postoperative Phase of Liver Resection in Neoplastic Patients: A Prospective Study Using the New-Generation TEGJournal of clinical medicine · 2025Article
- [Update on point-of-care-based coagulation treatment : Systems, reagents, device-specific treatment algorithms].Die Anaesthesiologie · 2024Review
- Understanding the systemic effects of intrapleural tPA and DNase by evaluating effects on coagulation.Journal of thoracic disease · 2024Article
- Analyzing venous thromboembolism risk in malignant tumors: thromboelastogram and coagulation factors study.Biomarkers in medicine · 2024Article
- Modified Thromboelastography for Peri-interventional Assessment of Platelet Function in Cardiology Patients: A Narrative Review.Seminars in thrombosis and hemostasis · 2023Review
- Viscoelastic testing: an illustrated review of technology and clinical applications.Research and practice in thrombosis and haemostasis · 2023Review
- Changes of Coagulation and Fibrinolytic Status Detected by Thromboelastography (TEG6sHealthcare (Basel, Switzerland) · 2022Article
- Comparison of assessment of coagulation in healthy dogs by the TEG 6s and TEG 5000 viscoelastic analyzers.Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc · 2022Article
- The Use of Thromboelastography in Percutaneous Coronary Intervention and Acute Coronary Syndrome in East Asia: A Systematic Literature Review.Journal of clinical medicine · 2022Review
- Operability of a Resonance-Based Viscoelastic Haemostatic Analyzer in the High-Vibration Environment of Air Medical Transport.Journal of clinical medicine · 2022Article
- Use of thromboelastography before the administration of hemostatic agents to safely taper recombinant activated factor VII in acquired hemophilia A: a report of three cases.Thrombosis journal · 2022Article
- Viscoelastic Hemostatic Assays: A Primer on Legacy and New Generation Devices.Journal of clinical medicine · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
19 authors.
Funding
Abstract
backgroundTrauma-induced coagulopathy is a major driver of mortality following severe injury. Viscoelastic goal-directed resuscitation can reduce mortality after injury. The TEG 5000 system is widely used for viscoelastic testing. However, the TEG 6s system incorporates newer technology, with encouraging results in cardiovascular interventions. The purpose of this study was to validate the TEG 6s system for use in trauma patients.
methodsMulticenter noninvasive observational study for method comparison conducted at 12 US Levels I and II trauma centers. Agreement between the TEG 6s and TEG 5000 systems was examined using citrated kaolin reaction time (CK.R), citrated functional fibrinogen maximum amplitude (CFF.MA), citrated kaolin percent clot lysis at 30 minutes (CK.LY30), citrated RapidTEG maximum amplitude (CRT.MA), and citrated kaolin maximum amplitude (CK.MA) parameters in adults meeting full or limited trauma team criteria. Blood was drawn ≤1 hour after admission. Assays were repeated in duplicate. Reliability (TEG 5000 vs. TEG 6s analyzers) and repeatability (interdevice comparison) was quantified. Linear regression was used to define the relationship between TEG 6s and TEG 5000 devices.
resultsA total of 475 patients were enrolled. The cohort was predominantly male (68.6%) with a median age of 49 years. Regression line slope estimates (ß) and linear correlation estimates (p) were as follows: CK.R (ß = 1.05, ρ = 0.9), CFF.MA (ß = 0.99, ρ = 0.95), CK.LY30 (ß = 1.01, ρ = 0.91), CRT.MA (TEG 6s) versus CK.MA (TEG 5000) (ß = 1.06, ρ = 0.86) as well as versus CRT.MA (TEG 5000) (ß = 0.93, ρ = 0.93), indicating strong reliability between the devices. Overall, within-device repeatability was better for TEG 6s versus TEG 5000, particularly for CFF.MA and CK.LY30.
conclusionThe TEG 6s device appears to be highly reliable for use in trauma patients, with close correlation to the TEG 5000 device and equivalent/improved within-device reliability. Given the potential advantages of using the TEG 6s device at the site of care, confirmation of agreement between the devices represents an important advance in diagnostic testing. LEVEL OF EVIDENCE: Diagnostic test, level II.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials