Evidence map›Paper›PMID 31737618›Full record

ArticleFrontiers in bioengineering and biotechnology2019

Development of a Cuvette-Based LSPR Sensor Chip Using a Plasmonically Active Transparent Strip.

Seo Yeong Oh, Nam Su Heo, Vivek K Bajpai, Sung-Chan Jang, Gyeongsik Ok, Youngjin Cho, Yun Suk Huh

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Review
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Seo Yeong OhDepartment of Biological Engineering, Inha University, Incheon, South Korea.
Nam Su HeoDepartment of Biological Engineering, Inha University, Incheon, South Korea.
Vivek K BajpaiDepartment of Energy and Materials Engineering, Dongguk University-Seoul, Seoul, South Korea.
Sung-Chan JangDepartment of Biological Engineering, Inha University, Incheon, South Korea.
Gyeongsik OkResearch Group of Consumer Safety, Korea Food Research Institute, Wanju-gun, South Korea.
Youngjin ChoResearch Group of Consumer Safety, Korea Food Research Institute, Wanju-gun, South Korea.
Yun Suk HuhDepartment of Biological Engineering, Inha University, Incheon, South Korea.
Inha University · KRKorea Food Research Institute · KRDongguk University · KRKorea Basic Science Institute · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This research demonstrates the development of a transmission-mode localized surface plasmon resonance (LSPR) sensor chip using a cuvette cell system for the sensitive detection of a biomolecule marker such as C-reactive protein (CRP). In order to develop a highly sensitive LSPR sensor chip, plasmonically active gold nanoparticles (AuNPs) were decorated onto various transparent substrates in the form of a uniform, high-density single layer using a self-assembly process. The transparent substrate surface was modified with amine functional groups via (3-Aminopropyl)triethoxysilane (APTES) treatment, and the ligand concentration and temperature (0.5% APTES at 60°C) were then optimized to control the binding energy with AuNPs. The optimized plasmonically active strip was subsequently prepared by dipping the amine-functionalized substrate into AuNPs for 8 h. The optimized plasmonic strip functionalized with anti-CRP was transformed into a portable LSPR sensor chip by placing it inside a cuvette cell system, and its detection performance was evaluated using CRP as a model sample. The detection limit for CRP using our LSPR sensor chip was 0.01 μg/mL, and the detection dynamic range was 0.01-10 μg/mL with a %CV of <10%, thus confirming its selectivity and good reproducibility. These findings illustrate that the highly sensitive portable LSPR biosensor developed in this study is expected to be widely used in a diverse range of fields such as diagnosis, medical care, environmental monitoring, and food quality control.

Indexed as

C-reactive protein (CRP)localized surface plasmon resonance (LSPR)plasmon chipportable sensor chipself-assembly method

Identifiers

PMID31737618
PMCPMC6839135
OpenAlexW2981554418

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.