Evidence map›Paper›PMID 31737520›Full record

ArticleCardiovascular diagnosis and therapy2019

Integrated use of cardiac MRI and the CardioMEMS™ HF system in PAH: the utility of coincident pressure and volume in RV failure-the NHLBI-VITA trial.

Robert W W Biederman, Mark Doyle, Priscilla Correa-Jaque, Geetha Rayarao, Raymond L Benza

Open access · diamondAbstract read
In one paragraph

Article in Cardiovascular diagnosis and therapy, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Robert W W BiedermanAllegheny General Hospital, Pittsburgh, PA, USA.
Mark DoyleAllegheny General Hospital, Pittsburgh, PA, USA.
Priscilla Correa-JaqueAllegheny General Hospital, Pittsburgh, PA, USA.
Geetha RayaraoAllegheny General Hospital, Pittsburgh, PA, USA.
Raymond L BenzaAllegheny General Hospital, Pittsburgh, PA, USA.
Allegheny General Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aims to study the feasibility and safety of measuring volumetric and pressure parameters noninvasively using simultaneous cardiovascular magnetic resonance (cMR) volumetric data and time-resolved pressure waveforms from previously implanted CardioMEMS devices in pulmonary arterial hypertension (PAH) patients. Opportunities to intervene during clinically occult phases in PAH promise to herald a key transformation in our current practice for treating this complex population. Currently, it is possible and convenient to monitor daily pulmonary arterial (PA) pressures in PAH patients using the CardioMEMS device to determine clinically silent progression. Supplementation of these pressures with other prognostic measurements of right ventricular (RV) contractility, PA resistance and RV/PA coupling could add further predictive capabilities.

methodsPAH patients (n=17) with New York Hospital Association (NYHA) class III or IV heart failure (HF) and recent HF related hospitalizations were implanted with the CardioMEMS device as part of a NHLBI sponsored Trial. Implanted patients were then assessed using cMR imaging of the right ventricle (RV) along with measurement of pulmonary artery flow. Patients were imaged at one-month post implant (baseline) and at 4-month follow-up time (n=12). At baseline, patients were studied at rest and then under three different physiologic conditions: inhaled nitric oxide (INO), dobutamine (Dob) stress and volumetric stress (Vol), using a multiple slice short-axis imaging and a rapid imaging protocol.

resultsAll patients were safely imaged, with no artifacts obscuring the cMR images. RV volumes were measured successfully at rest and under each stress condition using a reduced scan approach that required calibration for each patient which achieved a correlation r

conclusionsIt is safe and feasible to perform cMR imaging with simultaneous pulmonary artery pressure readings from the CardioMEMS device. A reduced scan approach was developed to allowed measurement of RV volumes during stress conditions. Volumetric and pressure measurements can be combined to assess fundamental myocardial properties (e.g., Emax, Ea and VVC) in PAH patients serially over time. In the future, these parameters can be tested as serial predictors of outcome and response to therapies in PAH.

Indexed as

Cardiac imagingimplantspressurepulmonary artery

Identifiers

PMID31737520
PMCPMC6837909
OpenAlexW2979883632

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.