Evidence map›Paper›PMID 31737355›Full record

ArticleJournal of ophthalmology2019

Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST.

Lisa Ramm, Robert Herber, Eberhard Spoerl, Frederik Raiskup, Lutz E Pillunat, Naim Terai

Open access · goldAbstract read
In one paragraph

Article in Journal of ophthalmology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.2field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Lisa RammDepartment of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden Fetscherstraße 74, 01307 Dresden, Germany.ORCID https://orcid.org/0000-0002-0183-8046
Robert HerberDepartment of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden Fetscherstraße 74, 01307 Dresden, Germany.
Eberhard SpoerlDepartment of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden Fetscherstraße 74, 01307 Dresden, Germany.ORCID https://orcid.org/0000-0003-3229-3795
Frederik RaiskupDepartment of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden Fetscherstraße 74, 01307 Dresden, Germany.
Lutz E PillunatDepartment of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden Fetscherstraße 74, 01307 Dresden, Germany.
Naim TeraiDepartment of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden Fetscherstraße 74, 01307 Dresden, Germany.
University Hospital Carl Gustav Carus · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST (CST) in healthy subjects.

methodsIn a prospective, observational study, IOP measurements with GAT (GAT-IOPc), ORA (IOPcc), DCT (DCT-IOP), and CST (bIOP) were performed and analyzed in 94 healthy subjects.

resultsMean age of the participants was 45.6 ± 17.2 years (range 18 to 81 years). Mean GAT-IOPc was 12.9 ± 2.4 mmHg, mean DCT-IOP was 16.1 ± 2.6 mmHg, and mean IOPcc was 15.6 ± 3.3 mmHg. DCT-IOP and IOPcc were significantly higher than GAT-IOPc (

conclusionAll tonometry devices showed a good agreement of biomechanical corrected IOP values with GAT-IOPc. As no influence of CCT on IOPcc, DCT-IOP, and bIOP was detectable, the used correction algorithms appear to be appropriate in these tonometers in the clinical setting. The highest agreement was found between GAT-IOPc and bIOP. However, bIOP weakly correlated with participants' age. Further studies are needed to elucidate the role of bIOP for IOP measurement.

Identifiers

PMID31737355
PMCPMC6815996
OpenAlexW2980891697

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.