ArticleActa biomaterialia2020
Integration of polarized spatial frequency domain imaging (pSFDI) with a biaxial mechanical testing system for quantification of load-dependent collagen architecture in soft collagenous tissues.
Article in Acta biomaterialia, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 48 citations in OpenAlex.
- Multi-axial strain mapping to characterise structure and material properties of the human hip capsule.PloS one · 2026Article
- HETEROGENEOUS PERIDYNAMIC NEURAL OPERATORS: DISCOVER BIOTISSUE CONSTITUTIVE LAW AND MICROSTRUCTURE FROM DIGITAL IMAGE CORRELATION MEASUREMENTS.Foundations of data science (Springfield, Mo.) · 2025Article
- FEBio FINESSE: An Open-Source Finite Element Simulation Approach to Estimate In Vivo Heart Valve Strains Using Shape Enforcement.Annals of biomedical engineering · 2025Article
- Quantified planar collagen distribution in healthy and degenerative mitral valve: biomechanical and clinical implications.Scientific reports · 2024Article
- Force Profiles of Single Ventricle Atrioventricular Leaflets in Response to Annular Dilation and Leaflet Tethering.Seminars in thoracic and cardiovascular surgery · 2024Article
- An investigation of how specimen dimensions affect biaxial mechanical characterizations with CellScale BioTester and constitutive modeling of porcine tricuspid valve leaflets.Journal of biomechanics · 2023Article
- An inverse fitting strategy to determine the constrained mixture model parameters: application in patient-specific aorta.Frontiers in bioengineering and biotechnology · 2023Article
- Spatial frequency domain Mueller matrix imaging.Journal of biomedical optics · 2022Article
- Benchtop characterization of the tricuspid valve leaflet pre-strains.Acta biomaterialia · 2022Article
- Ex vivo experimental characterizations for understanding the interrelationship between tissue mechanics and collagen microstructure of porcine mitral valve leaflets.Journal of the mechanical behavior of biomedical materials · 2022Article
- Linking the region-specific tissue microstructure to the biaxial mechanical properties of the porcine left anterior descending artery.Acta biomaterialia · 2022Article
- Linking collagen fiber architecture to tissue-level biaxial mechanical behaviors of porcine semilunar heart valve cusps.Journal of the mechanical behavior of biomedical materials · 2022Article
- AnData in brief · 2021Article
- Quantifying optical anisotropy in soft tissue membranes using Mueller matrix imaging.Journal of biomedical optics · 2021Article
- Parameterization, geometric modeling, and isogeometric analysis of tricuspid valves.Computer methods in applied mechanics and engineering · 2021Article
- Evaluation of affine fiber kinematics in porcine tricuspid valve leaflets using polarized spatial frequency domain imaging and planar biaxial testing.Journal of biomechanics · 2021Article
- A pilot study on biaxial mechanical, collagen microstructural, and morphological characterizations of a resected human intracranial aneurysm tissue.Scientific reports · 2021Article
- Instant polarized light microscopy for imaging collagen microarchitecture and dynamics.Journal of biophotonics · 2021Article
- Full-Range Optical Imaging of Planar Collagen Fiber Orientation Using Polarized Light Microscopy.BioMed research international · 2021Article
- A pilot in silico modeling-based study of the pathological effects on the biomechanical function of tricuspid valves.International journal for numerical methods in biomedical engineering · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 4 institutions in 3 countries.
Funding
Abstract
Collagen fiber networks provide the structural strength of tissues, such as tendons, skin and arteries. Quantifying the fiber architecture in response to mechanical loads is essential towards a better understanding of the tissue-level mechanical behaviors, especially in assessing disease-driven functional changes. To enable novel investigations into these load-dependent fiber structures, a polarized spatial frequency domain imaging (pSFDI) device was developed and, for the first time, integrated with a biaxial mechanical testing system. The integrated instrument is capable of a wide-field quantification of the fiber orientation and the degree of optical anisotropy (DOA), representing the local degree of fiber alignment. The opto-mechanical instrument''s performance was assessed through uniaxial loading on tendon tissues with known collagen fiber microstructures. Our results revealed that the bulk fiber orientation angle of the tendon tissue changed minimally with loading (median ± 0.5*IQR of 52.7° ± 3.3° and 51.9° ± 3.3° under 0 and 3% longitudinal strains, respectively), whereas on a micro-scale, the fibers became better aligned with the direction of loading: the DOA (mean ± SD) increased from 0.149 ± 0.032 to 0.198 ± 0.056 under 0 and 3% longitudinal strains, respectively, p < 0.001. The integrated instrument was further applied to study two representative mitral valve anterior leaflet (MVAL) tissues subjected to various biaxial loads. The fiber orientations within these representative MVAL tissue specimens demonstrated noticeable heterogeneity, with the local fiber orientations dependent upon the sample, the spatial and transmural locations, and the applied loading. Our results also showed that fibers were generally better aligned under equibiaxial (DOA = 0.089 ± 0.036) and circumferentially-dominant loading (DOA = 0.086 ± 0.037) than under the radially-dominant loading (DOA = 0.077 ± 0.034), indicating circumferential predisposition. These novel findings exemplify a deeper understanding of the load-dependent collagen fiber microstructures obtained through the use of the integrated opto-mechanical instrument. STATEMENT OF SIGNIFICANCE: In this study, a novel quantitative opto-mechanical system was developed by combining a polarized Spatial Frequency Domain Imaging (pSFDI) device with a biaxial mechanical tester. The integrated system was used to quantify the load-dependent collagen fiber microstructures in representative tendon and mitral valve anterior leaflet (MVAL) tissues. Our results revealed that MVAL's fiber architectures exhibited load-dependent spatial and transmural heterogeneities, suggesting further microstructural complexity than previously reported in heart valve tissues. These novel findings were possible through the system's ability to, for the first time, capture the load-dependent collagen architecture in the mitral valve anterior leaflet tissue over a wide field of view (e.g., 10 × 10 mm for the MVAL tissue specimens). Such capabilities afford unique future opportunities to improve patient outcomes through concurrent mechanical and microstructural assessments of healthy and diseased tissues in conditions such as heart valve regurgitation and calcification.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.