Evidence map›Paper›PMID 31734342›Full record

ArticleThe Journal of infection2020

Ingestible sensors correlate closely with peripheral temperature measurements in febrile patients.

Fanyu Huang, Chloe Magnin, Philippe Brouqui

Open access · hybridAbstract read
In one paragraph

Article in The Journal of infection, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Fanyu HuangDepartment of Research Microbes Evolution Phylogeny and Infections (MEPHI), The Institute for Development Research (IRD), University Hospital Institute-Mediterranean infection, Aix Marseille University, 19-21 Boulevard Jean MOULIN, 13005 Marseille, France. Electronic address: fanyu.huang@etu.univ-amu.fr.
Chloe MagninDepartment of Research Microbes Evolution Phylogeny and Infections (MEPHI), The Institute for Development Research (IRD), University Hospital Institute-Mediterranean infection, Aix Marseille University, 19-21 Boulevard Jean MOULIN, 13005 Marseille, France. Electronic address: chloe_magnin@yahoo.fr.
Philippe BrouquiDepartment of Research Microbes Evolution Phylogeny and Infections (MEPHI), The Institute for Development Research (IRD), University Hospital Institute-Mediterranean infection, Aix Marseille University, 19-21 Boulevard Jean MOULIN, 13005 Marseille, France. Electronic address: philippe.brouqui@univ-amu.fr.
Aix-Marseille Université · FRInstitut de Recherche pour le Développement · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundsReliable non-invasive methods for measuring body temperature are essential for the diagnosis and monitoring of infectious disease.

methodsThis study used Intraclass Correlation Coefficients (ICC) and the Bland- Altman plot to analyse the agreement between temperature measurements using an ingestible capsule sensor, a skin sensor and two non-invasive peripheral temperature measurements (axillary and infrared non-contact), collected from a population of febrile patient admitted for infectious disease.

resultsOf the 77 febrile patients screened, 26 patients were enrolled. The ICC between axillary temperature measurements (Taxi) vs. non-contact measurements (Tno-c) were 0.34 [-0.18; 0.63], 0.87 [0.55; 0.94] between Taxi vs. ingestible capsule measurements (Tcap) and 0.12 [-0.09; 0.37] between Taxi vs. Tetac. The mean difference between Taxi vs Tno-c was -1.18 °C with limits of agreement (LoA) from -2.96 to 0.58 °C. The mean difference between Taxi vs Tcap was 0.48 °C, with LoA from -0.60 to 1.56 °C. The mean difference between Taxi vs Tetac was -4.23 °C with LoA from -7.22 to -1.23 °C.

conclusionsIngestible capsule measurements are reliable enough to adequately estimate the core body temperature in clinical practice. Its non-invasiveness, and the real-time remote control offer new opportunities for future research into fever during infectious diseases.

Indexed as

Body TemperatureFeverHumansTemperatureBody temperature measurementFebrile patientIngestible capsule sensorPeripheral temperatureSkin sensor

Identifiers

PMID31734342
PMCPMC7112658
OpenAlexW2988446507

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.