Evidence map›Paper›PMID 31732818›Full record

ArticleNeurosurgical review2021

Technical limitations and pitfalls of diffusion-weighted imaging in intraoperative high-field MRI.

Constantin Roder, Patrick Haas, Marcos Tatagiba, Ulrike Ernemann, Benjamin Bender

Abstract read
PubMed Publisher
In one paragraph

Article in Neurosurgical review, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Intraoperative MR Imaging during Glioma Resection.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022
    Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Constantin RoderDepartment of Neurosurgery, University Hospital Tübingen, Eberhard Karls University, Hoppe-Seyler-Str. 3, D-72076, Tübingen, Germany.
Patrick HaasDepartment of Neurosurgery, University Hospital Tübingen, Eberhard Karls University, Hoppe-Seyler-Str. 3, D-72076, Tübingen, Germany. Patrick.haas@med.uni-tuebingen.de.ORCID http://orcid.org/0000-0001-7728-2091
Marcos TatagibaDepartment of Neurosurgery, University Hospital Tübingen, Eberhard Karls University, Hoppe-Seyler-Str. 3, D-72076, Tübingen, Germany.
Ulrike ErnemannDepartment of Neuroradiology, Eberhard Karls University, Tübingen, Germany.
Benjamin BenderDepartment of Neuroradiology, Eberhard Karls University, Tübingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveImage quality in high-field intraoperative MRI (iMRI) is often influenced negatively by susceptibility artifacts. While routine sequences are rather robust, advanced imaging such as diffusion-weighted imaging (DWI) is very sensitive to susceptibility resulting in insufficient imaging data. This study aims to analyze intraoperatively acquired DWI to identify the main factors for susceptibility, to compare results with postoperative images and to identify technical aspects for improvement of intraoperative DWI.

methods100 patients with intraaxial lesions operated in a high-field iMRI were analyzed retrospectively for the quality of intraoperative DWI in comparison to the postoperative scan. General quality of the MR scan, individual diffusion restrictions, artifacts, and their causes were analyzed.

resultsInclusion criteria were met in 78 patients, 124 diffusion restrictions were included in the comparative analysis. PPV and NPV for the detection of DWI changes intraoperatively were 0.94 and 0.56, respectively (SEN 0.94; SPE 0.56). Image quality was rated significantly (p < 0.0001) worse intraoperatively compared to the postoperative MRI. The main reasons for reduced image quality intraoperatively were air (64%) and artificial material (e.g., compress) (38%) in the resection cavity, as well as positioning of patient's head outside the MR's isocenter 37%. Analysis of surgical approaches showed that frontal craniotomies have the highest risk of limited image quality (40%), whereat better results (15% limited image quality) were seen for all other approaches (p = 0.059).

conclusionIntraoperative DWI showed reliable results in this analysis. However, image-quality was limited severely in many cases leading to uncertainty in the interpretation. Susceptibility-causing factors might be prevented in many cases, if the surgical team is aware of them. The most important factors are good filling of the resection cavity with irrigation fluid, not placing artificial materials in the resection cavity and adequate positioning of patient's head according to the MR isocenter.

Indexed as

ArtifactsAdultAgedBrain NeoplasmsChildDiffusion Magnetic Resonance ImagingFemaleHumansMagnetic Resonance ImagingMaleMiddle AgedMonitoring, IntraoperativeReproducibility of ResultsRetrospective StudiesDiffusion-weighted imagingIntraoperative MRINeurosurgery

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.