ArticleClinical neuroradiology2020
Long-term Angiographic Results of the Low-profile Acandis Acclino Stent for Treatment of Intracranial Aneurysms : A Multicenter Study.
Article in Clinical neuroradiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 13 citations in OpenAlex.
- Real-world use of the pEGASUS-HPC stent in cerebral aneurysms: results from a multicenter retrospective series.Neuroradiology · 2026Observational
- Safety and efficacy of the fourth-generation Acandis Acclino flex plus stent for the treatment of complex intracranial aneurysms.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Long-term results of wide-necked intracranial bifurcation aneurysms treated with stent-assisted coiling using low-profile acandis acclino stents.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2023Article
- Propensity score-adjusted analysis on stent-assisted coiling versus coiling alone for ruptured intracranial aneurysms.Scientific reports · 2021Article
- Endovascular Treatment of Intracranial Aneurysms.Life (Basel, Switzerland) · 2021Review
- Low-Profile Laser-Cut Stents for Endovascular Treatment of Intracranial Aneurysms : Incidence, Clinical Presentation and Risk Factors of Thromboembolic Events.Clinical neuroradiology · 2021Article
- Single Center Experience in Stent-Assisted Coiling of Complex Intracranial Aneurysms Using Low-Profile Stents : The ACCLINO® Stent Versus the ACCLINO® Flex Stent.Clinical neuroradiology · 2021Article
- Periprocedural Safety and Feasibility of the New LVIS EVO Device for Stent-Assisted Coiling of Intracranial Aneurysms: An Observational Multicenter Study.AJNR. American journal of neuroradiology · 2021Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe low-profile Acandis Acclino is a self-expandable nitinol microstent for stent-assisted coiling of intracranial aneurysms. This article reports long-term clinical and angiographic outcome in a multicenter setting.
methodsIn this study 98 consecutive patients (mean age 55.4 ± 13.5 years) were treated with the Acclino for 98 aneurysms (28 unruptured, 20 recurrent, 50 ruptured) at 3 German tertiary care centers within a 6-year period. The technical success, complications, clinical outcome and angiographic results were retrospectively analyzed.
resultsThe technical success rate was 100% with immediate complete occlusion achieved in 89.8% of the patients. Among 65 patients (66.3%) available for a 6‑month follow-up, complete and near-complete occlusion rates were 92.3% and 98.5%, respectively. In 38 patients (38.8%) with long-term follow-up (mean: 21 months), complete and near-complete occlusion were achieved in 81.2% and 89.5%, respectively. Aneurysm recurrence between mid-term and long-term follow-up was observed in 14.3%. The retreatment rate was 11.3%. There were three thromboembolic events (3.1%), of which one resulted in ischemic stroke (1.0%). For unruptured aneurysms, the procedural and device-related morbidity rates were 2.1% and 0%, respectively.
conclusionIn the present study, the Acclino was associated with a low risk of thromboembolic complications and high aneurysm occlusion rates at long-term follow-up. Due to incomplete angiographic follow-up in this series, prospective studies will be necessary to confirm the results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.