Evidence map›Paper›PMID 31732196›Full record

ArticleUltrasound in medicine & biology2020

Acoustic Parameters for Optimal Ultrasound-Triggered Release from Novel Spinal Hardware Devices.

Lauren J Delaney, Cemile Basgul, Daniel W MacDonald, Keith Fitzgerald, Noreen J Hickok, Steven M Kurtz, Flemming Forsberg

Abstract read
In one paragraph

Article in Ultrasound in medicine & biology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. In Vitro and In Vivo Evaluation of Ultrasound-Triggered Release From Novel Spinal Device.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2023
    Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lauren J DelaneyDepartment of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
Cemile BasgulSchool of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.
Daniel W MacDonaldSchool of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.
Keith FitzgeraldDepartment of Orthopaedic Surgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
Noreen J HickokDepartment of Orthopaedic Surgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
Steven M KurtzSchool of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA; Exponent, Inc., Philadelphia, Pennsylvania, USA.
Flemming ForsbergDepartment of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA. Electronic address: Flemming.fosberg@jefferson.edu.

Funding

Preventing Spinal Infection: Ultrasound Triggered ProphylaxisR01AR069119 · NIAMS · THOMAS JEFFERSON UNIVERSITY · PI Flemming Forsberg, Noreen J Hickok · 2016 to 2026
$3.2M
Synovial Fluid and Joint SepsisR01AR072513 · NIAMS · THOMAS JEFFERSON UNIVERSITY · PI HICKOK, NOREEN J · 2017 to 2021
$2.5M
Ultrasound-Triggered Prophylaxis as a Novel Paradigm for Preventing Spinal InfectionF32AR072491 · NIAMS · THOMAS JEFFERSON UNIVERSITY · PI DELANEY, LAUREN JO · 2018 to 2021
$189k
NIAMS NIH HHS F32 AR072491NIAMS NIH HHS R01 AR069119NIAMS NIH HHS R01 AR072513
6 · The paper itself

Abstract

Post-operative infection is a catastrophic complication of spinal fusion surgery, with rates as high as 10%, and existing preventative measures (i.e., peri-operative antibiotics) are only partially successful. To combat this clinical problem, we have designed a drug delivery system around polyether ether ketone clips to be used for prophylactic post-surgical release of antibiotics upon application of ultrasound. The overall hypothesis is that antimicrobial release from this system will aggressively combat post-surgical bacterial survival. This study investigated a set of acoustic parameters optimized for in vitro ultrasound-triggered coating rupture and subsequent release of encapsulated prophylactic antibiotics. We determined that a transducer frequency of 1.7 MHz produced the most consistent burst release and that, at this frequency, a pulse repetition frequency of 6.4 kHz and acoustic output power of 100% (3.41 MPa) produced the greatest release, representing an important proof of principle and the basis for continued development of this novel drug delivery system.

Indexed as

AcousticsAnti-Bacterial AgentsAntibiotic ProphylaxisBenzophenonesCapsulesDrug Delivery SystemsEquipment DesignPolymersUltrasonographyAnti-Bacterial AgentsBenzophenonesCapsulespolyetheretherketonePolymersInfectionPolyether ether ketoneUltrasound-triggered release

Identifiers

PMID31732196
PMCPMC7139856

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.