Evidence map›Paper›PMID 31731329›Full record

ArticleTurkish journal of medical sciences2020

Evaluation of a two-image technique consisting of an axial and a coronal image generated by using the rib-flattening application: effect on reading time and diagnostic validity

Koray Kiliç, Melih Akyüz, Emetullah Cindil, Nesrin Erdoğan, Gonca Erbaş, Mehmet Araç

Abstract read
In one paragraph

Article in Turkish journal of medical sciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Koray KiliçDepartment of Radiology, Faculty of Medicine, Gazi University, Ankara, TurkeyORCID 0000-0002-9015-1755
Melih AkyüzDepartment of Radiology, Faculty of Medicine, Gazi University, Ankara, TurkeyORCID 0000-0003-0853-3947
Emetullah CindilDepartment of Radiology, Faculty of Medicine, Gazi University, Ankara, TurkeyORCID 0000-0002-9345-1577
Nesrin ErdoğanDepartment of Radiology, Faculty of Medicine, Gazi University, Ankara, TurkeyORCID 0000-0002-3319-0301
Gonca ErbaşDepartment of Radiology, Faculty of Medicine, Gazi University, Ankara, TurkeyORCID 0000-0003-0788-9386
Mehmet AraçDepartment of Radiology, Faculty of Medicine, Gazi University, Ankara, TurkeyORCID 0000-0003-4058-1375

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background/aim: When reading a chest CT, a radiologist needs to evaluate each rib one by one due to complex curvy shape, which makes reporting a tiresome and time-consuming task. A new curved planar reformat application that flattens ribs on a single plane may find a place in the radiology reporting room. This study aimed to evaluate the effect of a two-image set created by using the rib-flattening application on the performance of a radiologist in detecting sclerotic rib lesions in cancer patients. Materials and methods: The local Institutional Review Board approved this retrospective study. Two radiologists with different experience levels reviewed chest CT examinations of 106 patients (76 men, 30 women). We divided the patients into group A (n = 54), reviewed by a standard method, and group B (n = 52), reviewed by a standard method and the two-image set created on the rib- flattening application. Reading times, validity indices, and agreement levels with reference data were evaluated for both readers. Results: The median reading time of the junior examiner significantly decreased with the rib-flattening method (160.5 s vs. 70.0 s; P < 0.001). Diagnostic indices of the senior reader were improved significantly at per patient level (group A, AUC: 0.867; group B, AUC: 0.982; P = 0.046). The new method showed better agreement levels (kappa: 0.69 to 0.96) than the general method (kappa: 0.53 to 0.91). Conclusion: Based on improved agreement levels, reading times, and diagnostic validity indices we conclude that a two-image set consisting of an axial and a coronal flattened-rib image may be used in conjunction with an ordinary exam.

Indexed as

AgedBone NeoplasmsFemaleHumansMaleMiddle AgedRadiography, ThoracicReproducibility of ResultsRetrospective StudiesRibsTomography, X-Ray Computedbone readingCTrib-flatteningrib metastasis

Identifiers

PMID31731329
PMCPMC7080368

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.