Evidence map›Paper›PMID 31728313›Full record

ArticleQuantitative imaging in medicine and surgery2019

Motion correction of chemical exchange saturation transfer MRI series using robust principal component analysis (RPCA) and PCA.

Chongxue Bie, Yuhua Liang, Lihong Zhang, Yingcheng Zhao, Yanrong Chen, Xueru Zhang, Xiaowei He, Xiaolei Song

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
0.6field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Chongxue BieSchool of Information Science and Technology, Northwest University, Xi'an 710127, China.
Yuhua LiangSchool of Information Science and Technology, Northwest University, Xi'an 710127, China.
Lihong ZhangSchool of Information Science and Technology, Northwest University, Xi'an 710127, China.
Yingcheng ZhaoSchool of Information Science and Technology, Northwest University, Xi'an 710127, China.
Yanrong ChenSchool of Information Science and Technology, Northwest University, Xi'an 710127, China.
Xueru ZhangSchool of Information Science and Technology, Northwest University, Xi'an 710127, China.
Xiaowei HeSchool of Information Science and Technology, Northwest University, Xi'an 710127, China.
Xiaolei SongSchool of Information Science and Technology, Northwest University, Xi'an 710127, China.
Northwest University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundChemical exchange saturation transfer (CEST) MRI requires the acquisition of multiple saturation-weighted images and can last several minutes. Misalignments among these images, which are often due to the inevitable motion of the subject, will corrupt CEST contrast maps and result in large quantification errors. Therefore, the registration of the CEST series is critical. However, registration is challenging since common intensity-based registration algorithms may fail to differentiate CEST signals from motion artifacts. Herein, we studied how different patterns of motion affect CEST quantification and proposed a cascaded two-step registration scheme by utilizing features extracted from the entire Z-spectral image series instead of direct registration to a single image.

methodsThe proposed approach is conducted in two stages: during the first coarse registration, the Z-spectral image series is decomposed by robust principal component analysis (RPCA) to separate CEST contrast from motion. The recomposed image series using only the low-rank component, which contains minimized motion, are averaged to generate a reference for the alignment of the image series. To further remove residual misalignments, the coarse registration is followed by a refinement stage, which uses PCA iteratively to generate motionless synthetic reference series with the first few principal components (PCs) that correspond to CEST contrast. In the end, the quality check is performed to exclude the images with unsuccessful registration.

resultsThe proposed registration scheme (RPCA + PCA_R) was assessed by both phantom experiments and

conclusionsThe registration scheme of RPCA + PCA_R provides robust motion correction between two specific Z-spectral images and among an entire image series, through extraction of the static component from the entire Z-spectra set and inclusion of a PCA-based refinement step. Therefore, this method can help improve CEST acquisition and quantification.

Indexed as

Chemical exchange saturation transfer (CEST)motion correctionprincipal component analysis (PCA)robust principal component analysis (RPCA)

Identifiers

PMID31728313
PMCPMC6828584
OpenAlexW2981002293

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.