Does nonexistent of your hands on the screen guarantee no radiation exposure to your body? - Study on exposure of the practitioner's hands to radiation during C-arm fluoroscopy-guided injections and effectiveness of a new shielding device.

Jae-Eun Lee, Ju-Hyun Kim, Su-Jin Lee, Mingeon Kim, Tae-Woo Nam, Chul Hyun Kim, Tae-Du Jung, Jong-Moon Hwang

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Jae-Eun LeeDepartment of Rehabilitation Medicine, Kyungpook National University Hospital.
Ju-Hyun KimDepartment of Rehabilitation Medicine, Kyungpook National University Hospital.
Su-Jin LeeGraduate School of Public Health, Kyungpook National University.
Mingeon KimDepartment of Advanced Technology, Medical Imaging Team, Daegu-Gyeongbuk Medical Innovation Foundation, South Korea.
Tae-Woo NamDepartment of Rehabilitation Medicine, Kyungpook National University Hospital.
Chul Hyun KimDepartment of Rehabilitation Medicine, Kyungpook National University Hospital.
Tae-Du JungDepartment of Rehabilitation Medicine, Kyungpook National University Hospital.
Jong-Moon HwangDepartment of Rehabilitation Medicine, Kyungpook National University Hospital.
Kyungpook National University Hospital · KRKyungpook National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Observational phantom study.This study aimed to evaluate the radiation exposure dose of practitioner's hands when performing C-arm guided procedures and to determine the usefulness of our newly designed radiation shielding device.C-arm guided procedures including lumbar transforaminal epidural steroid injections (TFESIs) are commonly used for pain control induced by lumbar radiculopathy. The practitioner's hands are vulnerable to radiation exposure because of the long exposure time and short distance from the radiation resource. No studies to date have reported the cumulative exposure of the physician's hands according to location and exposure time.Using a chest phantom irradiated with X-rays under lumbar TFESI conditions, cumulative scatter radiation dose was measured at 36 points using a dosimeter. The measurements were checked at 1, 3, 5, 10 minutes of radiation exposure. The experiment was repeated using our newly designed shielding device.Significant radiation accumulation was observed in the field where the practitioner's hands might be placed during C-arm guided procedures. The further the distance from the radiation resource and the shorter the exposure time, the smaller was the cumulative radiation expose dose. The new shielding device showed an excellent shielding rate (66.0%-99.9%) when the dosimeter was within the shielding range. However, at some points, increased accumulated radiation exposure dose was observed, although the dosimeter was within the range of the shielding device.To reduce radiation exposure of the practitioner's hands when performing C-arm-guided procedures, the radiation exposure time should be decreased and a greater distance from the radiation resource should be maintained. When using our shielding device, placing the hand close to the device surface and minimizing the time using fluoroscopy minimized the radiation exposure of the hand.

Indexed as

FluoroscopyHandHumansOccupational ExposurePhantoms, ImagingRadiation DosageRadiation ExposureRadiation ProtectionTomography, X-Ray ComputedXiphoid Bone