Evidence map›Paper›PMID 31722128›Full record

ArticleMagnetic resonance in medicine2020

Self-calibrated interpolation of non-Cartesian data with GRAPPA in parallel imaging.

Seng-Wei Chieh, Mostafa Kaveh, Mehmet Akçakaya, Steen Moeller

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Diffusion Imaging in the Post HCP Era.Journal of magnetic resonance imaging : JMRI · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Seng-Wei ChiehElectrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota.ORCID 0000-0003-2191-4699
Mostafa KavehElectrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota.
Mehmet AkçakayaElectrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota.
Steen MoellerCenter for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota.ORCID 0000-0003-1698-7260

Funding

TRD4 - Ultrahigh Field Engineering and SafetyP41EB027061 · NIBIB · UNIVERSITY OF MINNESOTA · PI Mehmet Akcakaya · 2019 to 2026
$11.7M
Elementary Neuronal Ensembles to Whole Brain Networks: Ultrahigh Resolution Imaging of Function and Connectivity in Humans - SUPPLEMENTU01EB025144 · NIBIB · UNIVERSITY OF MINNESOTA · PI UGURBIL, KAMIL · 2017 to 2022
$9.7M
NMR Imaging and SpectroscopyP41EB015894 · NIBIB · UNIVERSITY OF MINNESOTA · PI UGURBIL, KAMIL · 2012 to 2017
$8.4M
Novel Accelerated Contrast-Enhanced High Resolution Coronary MRIR00HL111410 · NHLBI · UNIVERSITY OF MINNESOTA · PI AKCAKAYA, MEHMET · 2015 to 2017
$746k
NHLBI NIH HHS R00 HL111410NIBIB NIH HHS P41 EB015894NIBIB NIH HHS P41 EB027061NIBIB NIH HHS U01 EB025144
6 · The paper itself

Abstract

purposeTo develop a non-Cartesian k-space reconstruction method using self-calibrated region-specific interpolation kernels for highly accelerated acquisitions.

methodsIn conventional non-Cartesian GRAPPA with through-time GRAPPA (TT-GRAPPA), the use of region-specific interpolation kernels has demonstrated improved reconstruction quality in dynamic imaging for highly accelerated acquisitions. However, TT-GRAPPA requires the acquisition of a large number of separate calibration scans. To reduce the overall imaging time, we propose Self-calibrated Interpolation of Non-Cartesian data with GRAPPA (SING) to self-calibrate region-specific interpolation kernels from dynamic undersampled measurements. The SING method synthesizes calibration data to adapt to the distinct shape of each region-specific interpolation kernel geometry, and uses a novel local k-space regularization through an extension of TT-GRAPPA. This calibration approach is used to reconstruct non-Cartesian images at high acceleration rates while mitigating noise amplification. The reconstruction quality of SING is compared with conjugate-gradient SENSE and TT-GRAPPA in numerical phantoms and in vivo cine data sets.

resultsIn both numerical phantom and in vivo cine data sets, SING offers visually and quantitatively similar reconstruction quality to TT-GRAPPA, and provides improved reconstruction quality over conjugate-gradient SENSE. Furthermore, temporal fidelity in SING and TT-GRAPPA is similar for the same acceleration rates. G-factor evaluation over the heart shows that SING and TT-GRAPPA provide similar noise amplification at moderate and high rates.

conclusionThe proposed SING reconstruction enables significant improvement of acquisition efficiency for calibration data, while matching the reconstruction performance of TT-GRAPPA.

Indexed as

Image EnhancementImage Processing, Computer-AssistedAlgorithmsBrainCalibrationMagnetic Resonance ImagingPhantoms, Imagingnon-Cartesian GRAPPAparallel imagingself-calibration

Identifiers

PMID31722128
PMCPMC6982601

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.