Evidence map›Paper›PMID 31722119›Full record

ArticleMagnetic resonance in medicine2020

Safe guidewire visualization using the modes of a PTx transmit array MR system.

Felipe Godinez, Greig Scott, Francesco Padormo, Joseph V Hajnal, Shaihan J Malik

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Felipe GodinezSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.ORCID 0000-0002-0951-8370
Greig ScottMagnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA.
Francesco PadormoGuy's and St. Thomas' NHS Foundation Trust, London, United Kingdom.
Joseph V HajnalSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Shaihan J MalikSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.ORCID 0000-0001-8925-9032
King's College London · GBGuy's and St Thomas' NHS Foundation Trust · GBResonance Research (United States) · US

Funding

Medical Research Council MR/N027949/1Wellcome Trust 203148Wellcome Trust 203148/Z/16/Z
6 · The paper itself

Abstract

purposeMRI-guided cardiovascular intervention using standard metal guidewires can produce focal tissue heating caused by induced radiofrequency guidewire currents. It has been shown that safe operation is made possible by using parallel transmit radiofrequency coils driven in the null current mode, which does not induce radiofrequency currents and hence allows safe tissue visualization. We propose that the maximum current modes, usually considered unsafe, be used at very low power levels to visualize conductive wires, and we investigate pulse sequences best suited for this application.

methodsSpoiled gradient echo, balanced steady-state free precession, and turbo spin echo sequences were evaluated for their ability to visualize a conductive guidewire embedded in a gel phantom when run in maximum current modes at very low power level. Temperature at the guidewire tip was monitored for safety assessment.

resultsExcellent guidewire visualization could be achieved using maximum current modes excitation, with the turbo spin echo sequence giving the best image quality. Although turbo spin echo is usually considered to be a high-power sequence, our method reduced all pulses to 1% amplitude (0.01% power), and heating was not detected. In addition, visualization of background tissue can be achieved using null current mode, also with no recorded heating at the guidewire tip even when running at 100% (reported) specific absorption rate.

conclusionParallel transmit is a promising approach for both guidewire and tissue visualization using maximum and null current modes, respectively, for interventional cardiac MRI. Such systems can switch excitation mode instantaneously, allowing for flexible integration into interactive sequences.

Indexed as

Magnetic Resonance ImagingMagnetic Resonance Imaging, InterventionalEquipment DesignPhantoms, ImagingRadio Wavesauxiliary PTx systemcardiac cathetersguidewire visualizationinterventional MRI catheterizationinvasive hemodynamicsmedical device heatingparallel transmit MRIreal-time MRI

Identifiers

PMID31722119
PMCPMC7048617
OpenAlexW2985548820

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.