ArticleSurgical endoscopy2020
A robotic flexible endoscope with shared autonomy: a study of mockup cholecystectomy.
Article in Surgical endoscopy, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 27 citations in OpenAlex.
- Augmenting colonoscopy with artificial intelligence and robotic assistance: a human-factors scoping review toward a task-based shared autonomy paradigm.Journal of robotic surgery · 2026Article
- Will your next surgeon be a robot? Autonomy and AI in robotic surgery.Science robotics · 2025Review
- An Actuated Variable-View Rigid Scope System to Assist Visualization in Diagnostic Procedures.IEEE journal of translational engineering in health and medicine · 2024Article
- Scope actuation system for articulated laparoscopes.Surgical endoscopy · 2023Article
- Imaging-Navigated Surgery.Advances in experimental medicine and biology · 2023Article
- Autonomous robotic laparoscopic surgery for intestinal anastomosis.Science robotics · 2022Article
- A Confidence-Based Supervised-Autonomous Control Strategy for Robotic Vaginal Cuff Closure.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and AutomationArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundEndoscope is the eye of surgeon in minimally invasive surgery (MIS). Prevailing handheld endoscopes are manually steered, which can cause endoscope-instrument fencing. Robotic endoscopes can reduce the fatigue but could not reduce collisions. Handheld endoscopes with a flexible bending tip can reduce the shaft pivoting and collisions. However, its steering is challenging. In this paper, we present a robotic flexible endoscope with auto-tracking function and compare it with the conventional rigid endoscopes.
methodsA robotic flexible endoscope (RFE) with shared autonomy is developed. The RFE could either track the instruments automatically or be controlled by a foot pedal. A mockup cholecystectomy was designed to evaluate the performance. Five surgeons were invited to perform the mockup cholecystectomy in an abdominal cavity phantom with a manual rigid endoscope (MRE), a robotic rigid endoscope (RRE), and the RFE. Space occupation, time consumption, and questionnaires based on the NASA task load index were adopted to evaluate the performances and compare the three endoscope systems. An ex vivo experiment was conducted to demonstrate the feasibility of using the RFE in a biological tissue environment.
resultsAll surgeons completed the mockup cholecystectomy with the RFE independently. Failure occurred in the cases involving the RRE and the MRE. Inside the body cavity, the space occupied when using the RFE is 17.28% and 23.95% (p < 0.05) of that when using the MRE and the RRE, respectively. Outside the body cavity, the space occupied when using the RFE is 14.60% and 15.53% (p < 0.05) of that by using MRE and RRE. Time consumed in the operations with MRE, RRE, and RFE are 28.3 s, 93.2 s and 34.8 s, respectively. Questionnaires reveal that the performance of the RFE is the best among the three endoscope systems.
conclusionsThe RFE provides a wider field of view (FOV) and occupies less space than rigid endoscopes.