ArticleJournal of the American Society for Mass Spectrometry2019
Enhanced Multiplexing in Fourier Transform Charge Detection Mass Spectrometry by Decoupling Ion Frequency from Mass to Charge Ratio.
Article in Journal of the American Society for Mass Spectrometry, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed.
- Optimization of Radially Segmented Ion Mirrors for High Resolution Charge Detection Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2026Article
- Standardized workflow for multiplexed charge detection mass spectrometry on orbitrap analyzers.Nature protocols · 2025Review
- Article
- Charge Detection Mass Spectrometry Reveals Conformational Heterogeneity in Megadalton-Sized Monoclonal Antibody Aggregates.Journal of the American Chemical Society · 2024Article
- Article
- Improved Signal Processing for Mass Shifting Ions in Charge Detection Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2024Article
- Single-Ion Mass Spectrometry for Heterogeneous and High Molecular Weight Samples.Journal of the American Chemical Society · 2024Review
- Multiple Ion Charge Extraction (MICE) for High-Throughput Charge Detection Mass Spectrometry.Analytical chemistry · 2024Article
- Combined Multiharmonic Frequency Analysis for Improved Dynamic Energy Measurements and Accuracy in Charge Detection Mass Spectrometry.Analytical chemistry · 2023Article
- Electrostatic Linear Ion Trap Optimization Strategy for High Resolution Charge Detection Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2023Article
- Dynamic Energy Measurements in Charge Detection Mass Spectrometry Eliminate Adverse Effects of Ion-Ion Interactions.Analytical chemistry · 2023Article
- Characterizing Heterogeneous Mixtures of Assembled States of the Tobacco Mosaic Virus Using Charge Detection Mass Spectrometry.Journal of the American Chemical Society · 2022Article
- Apodization Specific Fitting for Improved Resolution, Charge Measurement, and Data Analysis Speed in Charge Detection Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2022Article
- Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry.Analytical chemistry · 2022Article
- Applications of Charge Detection Mass Spectrometry in Molecular Biology and Biotechnology.Chemical reviews · 2022Review
- Approaches to Heterogeneity in Native Mass Spectrometry.Chemical reviews · 2022Review
- Direct observation of ion emission from charged aqueous nanodrops: effects on gaseous macromolecular charging.Chemical science · 2021Article
- Mass Spectrometry-Based Structural Virology.Analytical chemistry · 2021Review
- Native Mass Spectrometry of Membrane Proteins.Analytical chemistry · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Weighing single ions with charge detection mass spectrometry (CDMS) makes it possible to obtain the masses of molecules of essentially unlimited size even in highly heterogeneous samples, but producing a mass histogram that is representative of all of the components in a mixture requires substantial measurement time. Multiple ions can be trapped to reduce analysis time but ion signals can overlap. To determine the maximum gains in analysis speed possible with current instrumentation with multiple ion trapping, simulations calculating the frequency and overlap rate of ions with different mass, charge, and energy ranges were performed. For an analyte with a broad mass distribution, such as long chain polyethylene glycol (PEG, 8 MDa), gains in analysis speed of up to 160 times that of prior CDMS experiments are possible. For signals from homogeneous samples, ions with the same m/z have frequencies that overlap and interfere, reducing the effectiveness of multiplexing in experiments where ions have the same energy per charge. We show that by maximizing the decoupling of ion m/z from frequency using a broad range of ion energies, the rate of signal overlap is significantly reduced making it possible to trap more ions. Under optimum decoupling conditions, a measurement speed nearly 50 times greater than that of prior CDMS experiments is possible for RuBisCO (517 kDa). The reduction in overlap due to decoupling also results in more accurate quantitation in samples that contain multiple analytes with different concentrations.
Indexed as
Identifiers
31720975What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.