Evidence map›Paper›PMID 31720640›Full record

ArticleLab on a chip2019

Cell lysis via acoustically oscillating sharp edges.

Zeyu Wang, Po-Hsun Huang, Chuyi Chen, Hunter Bachman, Shuaiguo Zhao, Shujie Yang, Tony J Huang

Erratum issuedAbstract read
In one paragraph

Article in Lab on a chip, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Acoustic Rising Microbubbles for Efficient Liquid Operations.Cyborg and bionic systems (Washington, D.C.) · 2026
    Article
  2. Article
  3. [High stability enhanced ultrasonic microfluidic structure with flexible tip coupled bubbles].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Zeyu WangDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA. phhuang73@gmail.com tony.huang@duke.edu.
Po-Hsun HuangDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA. phhuang73@gmail.com tony.huang@duke.edu.
Chuyi ChenDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA. phhuang73@gmail.com tony.huang@duke.edu.
Hunter BachmanDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA. phhuang73@gmail.com tony.huang@duke.edu.ORCID 0000-0002-2356-5392
Shuaiguo ZhaoDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA. phhuang73@gmail.com tony.huang@duke.edu.
Shujie YangDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA. phhuang73@gmail.com tony.huang@duke.edu.
Tony J HuangDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA. phhuang73@gmail.com tony.huang@duke.edu.ORCID 0000-0003-1205-3313

Funding

Extracellular vesicles and their ncRNA cargo as markers of trophoblast injuryR01HD086325 · NICHD · MAGEE-WOMEN'S RES INST AND FOUNDATION · PI SADOVSKY, YOEL · 2015 to 2019
$3.6M
Enabling Efficient, Fast, Biocompatible Exosome Separation via AcoustofluidicsR01GM132603 · NIGMS · DUKE UNIVERSITY · PI HUANG, TONY JUN · 2019 to 2022
$1.7M
An integrated acoustofluidic droplet-sorting platform for classification of lymphocyte activity and functional phenotyping at single cell levelR01GM127714 · NIGMS · NORTHEASTERN UNIVERSITY · PI KONRY, TANIA TALI · 2018 to 2021
$1.2M
NICHD NIH HHS R01 HD086325NIGMS NIH HHS R01 GM127714NIGMS NIH HHS R01 GM132603
6 · The paper itself

Abstract

In this article, we demonstrate an acoustofluidic device for cell lysis using the acoustic streaming effects induced by acoustically oscillating sharp-edged structures. The acoustic streaming locally generates high shear forces that can mechanically rupture cell membranes. With the acoustic-streaming-derived shear forces, our acoustofluidic device can perform cell lysis in a continuous, reagent-free manner, with a lysis efficiency of more than 90% over a range of sample flow rates. We demonstrate that our acoustofluidic lysis device works well on both adherent and non-adherent cells. We also validate it using clinically relevant samples such as red blood cells infected with malarial parasites. Additionally, the unique capability of our acoustofluidic device was demonstrated by performing downstream protein analysis and gene profiling without additional washing steps post-lysis. Our device is simple to fabricate and operate while consuming a relatively low volume of samples. These advantages and other features including the reagent-free nature and controllable lysis efficiency make our platform valuable for many biological and biomedical applications, particularly for the development of point-of-care platforms.

Indexed as

AcousticsLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesErythrocytesHeLa CellsHumansJurkat Cells

Identifiers

PMID31720640
PMCPMC6934418

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.