Evidence map›Paper›PMID 31718655›Full record

ArticleJournal of translational medicine2019

Purification of viable peripheral blood mononuclear cells for biobanking using a robotized liquid handling workstation.

Luigi Coppola, Giovanni Smaldone, Alessandra Cianflone, Simona Baselice, Peppino Mirabelli, Marco Salvatore

Open access · goldAbstract read
In one paragraph

Article in Journal of translational medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.1field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Luigi CoppolaIRCCS SDN, Naples Via Emanuele Gianturco, 113, 80143, Naples, Italy.
Giovanni SmaldoneIRCCS SDN, Naples Via Emanuele Gianturco, 113, 80143, Naples, Italy.
Alessandra CianfloneIRCCS SDN, Naples Via Emanuele Gianturco, 113, 80143, Naples, Italy.
Simona BaseliceIRCCS SDN, Naples Via Emanuele Gianturco, 113, 80143, Naples, Italy.
Peppino MirabelliIRCCS SDN, Naples Via Emanuele Gianturco, 113, 80143, Naples, Italy. pmirabelli@sdn-napoli.it.ORCID 0000-0002-2183-7577
Marco SalvatoreIRCCS SDN, Naples Via Emanuele Gianturco, 113, 80143, Naples, Italy.
SDN Istituto di Ricerca Diagnostica e Nucleare · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe purification of peripheral blood mononuclear cells (PBMCs) by means of density gradient (1.07 g/mL) centrifugation is one of the most commonly used methods in diagnostics and research laboratories as well as in biobanks. Here, we evaluated whether it was possible to set up an automated protocol for PBMC purification using a programmable liquid handling robotized workstation (Tecan, Freedom EVO 150). We selected a population composed of 30 subjects for whom it was possible to dispose of two ethylenediaminetetraacetic acid (EDTA) vacutainer tubes containing unfractionated peripheral blood. The purification of PBMCs was performed in parallel using automated and manual workflows.

resultsAn automated workflow using the Freedom EVO 150 liquid handling workstation was generated for the isolation of PBMCs. This protocol allowed blood dilution in Dulbecco's phosphate-buffered saline (DPBS), stratification onto the density gradient, and the collection of PBMC rings after centrifugation. The comparison between the automated and manual methods revealed no significant differences after separation in terms of total mononuclear cell enrichment, red blood cell contamination, or leucocyte formula, including the percentage of lymphoid subpopulations as B, T and natural killer (NK) lymphocytes.

conclusionsOur results show that it is possible to set up an automated protocol for the isolation of PBMCs using a robotized liquid handling workstation. This automated protocol provided comparable results to the routinely used manual method. This automatic method could be of interest for those working in biobanking or industries involved in diagnostics and therapeutics field, to avoid operator-dependent errors as well as procedures standardization.

Indexed as

Biological Specimen BanksRoboticsAdultAgedAged, 80 and overAutomationCell SeparationCell SurvivalErythrocyte CountErythrocytesFemaleHumansLeukocytes, MononuclearLymphocytesMaleMiddle AgedBiobanksDiagnosticsLaboratory automationSamples processingWhite blood cells

Identifiers

PMID31718655
PMCPMC6852781
OpenAlexW2985657400

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked