Evidence map›Paper›PMID 31718016›Full record

ArticleDiagnostics (Basel, Switzerland)2019

Quantification of Carotid Intraplaque Hemorrhage: Comparison between Manual Segmentation and Semi-Automatic Segmentation on Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequences.

Young Ju Song, Hyo Sung Kwak, Gyung Ho Chung, Seongil Jo

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Young Ju SongDepartment of Radiology of Chonbuk National University Hospital, Jeon-ju 54907, Korea.ORCID 0000-0003-2088-9727
Hyo Sung KwakRadiology and Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Jeon-ju 54907, Korea.ORCID 0000-0002-7228-8117
Gyung Ho ChungRadiology and Research Institute of Clinical Medicine of Chonbuk National University-Biomedical Research Institute of Chonbuk National University Hospital, Jeon-ju 54907, Korea.
Seongil JoDepartment of Statistics (Institute of Applied Statistics), Chonbuk National University, Jeon-ju 54907, Korea.
Jeonbuk National University Hospital · KRJeonbuk National University · KR

Funding

This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education NRF-2017R1D1A3B03032390
6 · The paper itself

Abstract

purposeCarotid intraplaque hemorrhage (IPH) increases risk of territorial cerebral ischemic events, but different sequences or criteria have been used to diagnose or quantify carotid IPH. The purpose of this study was to compare manual segmentation and semi-automatic segmentation for quantification of carotid IPH on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequences.

methodsForty patients with 16-79% carotid stenosis and IPH on MPRAGE sequences were reviewed by two trained radiologists with more than five years of specialized experience in carotid plaque characterization with carotid plaque MRI. Initially, the radiologists manually viewed the IPH based on the MPRAGE sequence. IPH volume was then measured by three different semi-automatic methods, with high signal intensity 150%, 175%, and 200%, respectively, above that of adjacent muscle on the MPRAGE sequence. Agreement on measurements between manual segmentation and semi-automatic segmentation was assessed using the intraclass correlation coefficient (ICC).

resultsThere was near-perfect agreement between manual segmentation and the 150% and 175% criteria for semi-automatic segmentation in quantification of IPH volume. The ICC of each semi-automatic segmentation were as follows: 150% criteria: 0.861, 175% criteria: 0.809, 200% criteria: 0.491. The ICC value of manual vs. 150% criteria and manual vs. 175% criteria were significantly better than the manual vs. 200% criteria (

conclusionsThe ICC of 150% and 175% criteria for semi-automatic segmentation are more reliable for quantification of IPH volume. Semi-automatic classification tools may be beneficial in large-scale multicenter studies by reducing image analysis time and avoiding bias between human reviewers.

Indexed as

carotid atherosclerosiscarotid intraplaque hemorrhageMPRAGEsemi-automatic quantification

Identifiers

PMID31718016
PMCPMC6963393
OpenAlexW2980567787

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.