Evidence map›Paper›PMID 31715564›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2020

The Impact of Acoustic Clutter on Large Array Abdominal Imaging.

Nick Bottenus, Gianmarco F Pinton, Gregg Trahey

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Large-Array Deep Abdominal Imaging in Fundamental and Harmonic Mode.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2023
    Article
  7. Article
  8. Article
  9. Spatial Coherence in Medical Ultrasound: A Review.Ultrasound in medicine & biology · 2022
    Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Nick Bottenus
Gianmarco F Pinton
Gregg Trahey

Funding

Coherence-Based Fetal Ultrasonic ImagingR01EB017711 · NIBIB · DUKE UNIVERSITY · PI TRAHEY, GREGG E. · 2014 to 2025
$4.7M
Training in Medical ImagingT32EB001040 · NIBIB · DUKE UNIVERSITY · PI NIGHTINGALE, KATHRYN RADABAUGH · 2003 to 2018
$4.4M
Large aperture and wideband modular ultrasound arrays for the diagnosis of liver cancerR01CA211602 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FERRARA, KATHERINE W, TRAHEY, GREGG E. · 2017 to 2021
$3.3M
A Patient-Adaptive, High MI Abdominal ScannerR01EB026574 · NIBIB · DUKE UNIVERSITY · PI TRAHEY, GREGG E. · 2018 to 2021
$2.3M
NCI NIH HHS R01 CA211602NIBIB NIH HHS R01 EB017711NIBIB NIH HHS R01 EB026574NIBIB NIH HHS T32 EB001040
6 · The paper itself

Abstract

Abdominal imaging suffers from a particularly difficult acoustic environment-targets are located deep and overlying tissue layers with varying properties generate acoustic clutter. Increasing array size can overcome the penetration and lateral resolution problems in ideal conditions, but how the impact of clutter scales with increasing array extent is unknown and may limit the benefits in vivo. Previous ex vivo experimental work showed the promise of large arrays but was technically limited to a length of 6.4 cm and to only partial sampling of the array elements. We present an extension of those studies using the Fullwave simulation tool to create a 10 cm ×2 cm matrix array with full lateral element sampling. We used a numerical model of the abdomen based on the maps of tissue acoustical properties and found that propagation through the modeled abdominal layers generated on average 25.4 ns of aberration and 0.74 cm of reverberation clutter across the array extent. Growing the full aperture from 2 to 10 cm improved contrast by 8.6 dB and contrast-to-noise ratio by 22.9% in addition to significantly improving target resolution. Alternative array strategies that may be useful for implementation-mismatched aperture sizes or a swept synthetic aperture-also produced improved quality with growing aperture size. These results motivate the development of larger diagnostic imaging arrays for the purpose of high-resolution imaging in challenging environments.

Indexed as

AbdomenComputer SimulationFemaleHumansImage Processing, Computer-AssistedUltrasonographyVisible Human Projects

Identifiers

PMID31715564
PMCPMC7103500

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked