Evidence map›Paper›PMID 31712932›Full record

ArticleThe international journal of cardiovascular imaging2020

Combined use of electro-anatomic mapping system and intracardiac echocardiography to achieve zero-fluoroscopy catheter ablation for treatment of paroxysmal atrial fibrillation: a single centre experience.

Matevž Jan, David Žižek, Dimitrij Kuhelj, Nikola Lakič, Tine Prolič Kalinšek, Jernej Štublar, Luka Klemen, Andrej Pernat, Bor Antolič

Abstract read
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 2 pooled it
2.1field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 2 syntheses or guidelines pooled it, 24 citations in OpenAlex.

  1. Intracardiac Echocardiography during Invasive Electrophysiological Procedures: a Scientific Statement of the European Heart Rhythm Association of the ESC, and the European Association of Percutaneous Cardiovascular Interventions of the ESC.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Guideline
  2. Safety and efficacy of intracardiac echocardiography in atrial fibrillation ablation: a meta-analysis.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Pooled it
  3. Review
  4. Article
  5. The use of cardiac imaging in patients undergoing atrial fibrillation ablation.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2025
    Review
  6. Review
  7. Review
  8. Review
  9. Practical guidance to reduce radiation exposure in electrophysiology applying ultra low-dose protocols: a European Heart Rhythm Association review.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Review
  10. Higher than recommended lesion size index target values for pulmonary vein isolation result in better clinical outcomes in paroxysmal atrial fibrillation patients.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022
    Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Matevž JanCardiovascular Surgery Department, University Medical Centre Ljubljana, Zaloška 7, 1000, Ljubljana, Slovenia. matevz.jan@kclj.si.ORCID http://orcid.org/0000-0002-6379-9986
David ŽižekCardiology Department, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Dimitrij KuheljClinical Institute for Radiology, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Nikola LakičCardiovascular Surgery Department, University Medical Centre Ljubljana, Zaloška 7, 1000, Ljubljana, Slovenia.
Tine Prolič KalinšekCardiovascular Surgery Department, University Medical Centre Ljubljana, Zaloška 7, 1000, Ljubljana, Slovenia.
Jernej ŠtublarCardiovascular Surgery Department, University Medical Centre Ljubljana, Zaloška 7, 1000, Ljubljana, Slovenia.
Luka KlemenCardiology Department, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Andrej PernatCardiology Department, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Bor AntoličCardiology Department, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Ljubljana University Medical Centre · SI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fluoroscopy is the principal imaging method for catheter ablation (CA) of atrial fibrillation (AF). However, radiation exposure carries potential health risk to patients and operators alike. Our aim was to study safety and efficacy of zero-fluoroscopy CA of paroxysmal AF with a combined use of electroanatomic mapping system (EAM) and intracardiac echocardiography (ICE). In addition, impact of ICE/EAM automatic integration system and contact force (CF) sensing technology on procedural times were assessed. We included 144 consecutive patients (69% males, age 60 ± 10 years, BMI 29 ± 4,6) referred for CA of symptomatic paroxysmal AF. All procedures were performed only with EAM system and ICE. No fluoroscopy was used. The acute procedural success of complete pulmonary vein isolation was achieved in all patients (100%) and adverse events were detected in eight patients (5.6%). In 53 (37%) patients the use of ICE/EAM automatic integration system shortened procedural times compared to those performed without it (148 ± 35 vs. 187 ± 44 min, p < 0.05). Similarly, 89 (60%) procedures where CF sensing catheter was used were shorter compared to those performed without it (163 ± 41 vs. 188 ± 46 min, p < 0.05). Zero-fluoroscopy approach for treatment of paroxysmal AF seems feasible, safe, and acutely effective. Additional reduction of procedural times could be achieved with the use of ICE/EAM automatic integration system and CF sensing technology.

Indexed as

Action PotentialsCatheter AblationEchocardiographyElectrophysiologic Techniques, CardiacHeart RateAgedAtrial FibrillationFemaleFluoroscopyHumansMaleMiddle AgedOperative TimePredictive Value of TestsProspective StudiesPulmonary VeinsCatheter ablationElectro-anatomic mapping systemIntracardiac echocardiographyParoxysmal atrial fibrillationZero-fluoroscopy

Identifiers

PMID31712932
OpenAlexW2984471325

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.