Evidence map›Paper›PMID 31711509›Full record

ArticleHead & face medicine2019

Release kinetics of the model protein FITC-BSA from different polymer-coated bovine bone substitutes.

Julian Lommen, Lara Schorn, Alexis Landers, Henrik Holtmann, Karin Berr, Norbert R Kübler, Christoph Sproll, Majeed Rana, Rita Depprich

Open access · goldAbstract read
In one paragraph

Article in Head & face medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Julian LommenDepartment of Oral and Maxillofacial Surgery, Heinrich-Heine-University, Moorenstraße 5, 40225, Düsseldorf, Germany.
Lara SchornDepartment of Oral and Maxillofacial Surgery, Heinrich-Heine-University, Moorenstraße 5, 40225, Düsseldorf, Germany. lara.schorn@hhu.de.ORCID http://orcid.org/0000-0002-4301-0693
Alexis LandersDepartment of Oral and Maxillofacial Surgery, Evangelisches Krankenhaus Hattingen, Bredenscheider Straße 54, 45525, Hattingen, Germany.
Henrik HoltmannDepartment of Oral and Maxillofacial Surgery, Malteser Clinic St. Johannes, Johannisstraße 21, 47198, Duisburg, Germany.
Karin BerrDepartment of Oral and Maxillofacial Surgery, Heinrich-Heine-University, Moorenstraße 5, 40225, Düsseldorf, Germany.
Norbert R KüblerDepartment of Oral and Maxillofacial Surgery, Heinrich-Heine-University, Moorenstraße 5, 40225, Düsseldorf, Germany.
Christoph SprollDepartment of Oral and Maxillofacial Surgery, Heinrich-Heine-University, Moorenstraße 5, 40225, Düsseldorf, Germany.
Majeed RanaDepartment of Oral and Maxillofacial Surgery, Heinrich-Heine-University, Moorenstraße 5, 40225, Düsseldorf, Germany.
Rita DepprichDepartment of Oral and Maxillofacial Surgery, Heinrich-Heine-University, Moorenstraße 5, 40225, Düsseldorf, Germany.
Heinrich Heine University Düsseldorf · DEEvangelisches Krankenhaus Mettmann · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundControlled release of proteins bound to conventional bone substitutes is still insufficient. Therefore, this study evaluates in-vitro release kinetics of the model protein FITC-BSA (fluorescein conjugated bovine serum albumine) from insoluble bovine collagenous bone matrices (ICBM) with different polymer coatings. Analyzes aim at comparing FITC-BSA release from uncoated versus coated ICBM over time to find bone substitute coatings with consistent release profiles.

methodsRelease kinetics of FITC-BSA from uncoated as well as coated ICBM with five different polymers (RESOMER R 203 H, RG 503 H, RG 504 H, RG 505, L 206 S) were measured over a period of 11 days (d). Measurements were conducted after 6 h (h), 12 h, 24 h, 3 d, 5 d, 7 d, 9 d and 11 d with six samples for each coated ICBM. Two groups were formed (1) with and (2) without medium change at times of measurement. For each group ANOVA with post-hoc Bonferroni testing was used. Scanning electron microscopy assessed morphologic differences between ICBM coating.

resultsIn group 1 approx. 70% of FITC-BSA release from uncoated ICBM occurred after 6 h compared to approx. 50% in group 2. Only polymers with medium inherent viscosity, i.e. RESOMER RG 503 H, constantly showed significantly more FITC-BSA release throughout 11 d than uncoated ICBM (p = 0.007). The same was found for group 2 (p = 0.005). No significant differences between PLA and PLGA polymers were found. Scanning electron microscopy results indicate a weak adhesion of polymer coatings to ICBM explaining its rather weak retentive effect on overall FITC-BSA release.

conclusionsMedium molecular size polymers reduce the overall released FITC-BSA from ICBM over time. In clinical practice these polymers may prove ideal for bone substitute materials.

Indexed as

Bone SubstitutesPolymersSerum Albumin, BovineAnimalsCattleFluorescein-5-isothiocyanateKineticsMicroscopy, Electron, ScanningBone SubstitutesFluorescein-5-isothiocyanatefluorescein isothiocyanate bovine serum albuminPolymersSerum Albumin, BovineBovineCollagen matricesFITC-BSAPolymer-coatedRelease kinetics

Identifiers

PMID31711509
PMCPMC6844035
OpenAlexW2984573356

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.