ArticleTechnology in cancer research & treatment
Dosimetric Characterization of the Dual Layer MLC System for an O-Ring Linear Accelerator.
Article in Technology in cancer research & treatment. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Implementation of VMAT-based lattice spatially fractionated radiation therapy (SFRT) across linac platforms: Practical considerations for QA and motion management.Journal of applied clinical medical physics · 2026Article
- A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy.Medical physics · 2026Article
- A multi-institution performance assessment of a double-layer MLC.Journal of applied clinical medical physics · 2025Article
- Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation.Journal of applied clinical medical physics · 2025Article
- Independent monitor unit verification for dynamic flattened beam plans on the Halcyon linac.Journal of applied clinical medical physics · 2023Article
- Characterisation of in-room leakage and scattered radiation for the Varian Halcyon linear accelerator.Physical and engineering sciences in medicine · 2022Article
- Investigation of Halcyon multi-leaf collimator model in Eclipse treatment planning system: A focus on the VMAT dose calculation with the Acuros XB algorithm.Journal of applied clinical medical physics · 2022Article
- Comparison of sliding window and field-in-field techniques for tangential whole breast irradiation using the Halcyon and Synergy Agility systems.Radiation oncology (London, England) · 2021Article
- Unlocking a closed system: dosimetric commissioning of a ring gantry linear accelerator in a multivendor environment.Journal of applied clinical medical physics · 2021Article
- Article
- Feasibility of Coplanar VMAT for Brain Metastases Using Halcyon With Knowledge-based Planning from Non-coplanar Plan.In vivo (Athens, Greece)Article
- A Comprehensive Evaluation of the Application of the Halcyon(2.0) IMRT Technique in Long-Course Radiotherapy for Rectal Cancer.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The Halcyon is Varian's latest linear accelerator that offers a single 6X flattening-filter-free beam with a jawless design that features a new dual layer multileaf collimator system with faster speed and reduced transmission. Dosimetric characteristics of the dual layer multileaf collimator system including transmission, dosimetric leaf gap, and tongue and groove effects were measured. Ionization chambers, diode arrays, and an electronic portal imaging device were used to measure various multileaf collimator characteristics. Transmission through both multileaf collimator banks was found to be 0.008%, while the distal and proximal banks alone had transmission values of 0.4%. The penumbra was slightly sharper for fields using only the distal multileaf collimator bank but found to be largely independent of leaf position with values between 2.7 to 3.0 mm at d