Evidence map›Paper›PMID 31705461›Full record

ArticleHigh blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension2019

The Impact of Measurement Methods on Office Blood Pressure and Management of Hypertension in General Practice.

Julia Höller, Linda Elizabeth Villagomez Fuentes, Klaus Matthias, Reinhold Kreutz

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in High blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Office blood pressure measurement: A comprehensive review.Journal of clinical hypertension (Greenwich, Conn.) · 2021
    Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Julia HöllerAudorfer Gemeinschaftspraxis, General Medicine in Oberaudorf, Bavaria, Germany.
Linda Elizabeth Villagomez FuentesCharité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Institute of Clinical Pharmacology and Toxicology, Charitéplatz 1, 10117, Berlin, Germany. linda.villagomez@charite.de.
Klaus MatthiasAudorfer Gemeinschaftspraxis, General Medicine in Oberaudorf, Bavaria, Germany.
Reinhold KreutzCharité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität Berlin, and Institute of Clinical Pharmacology and Toxicology, Charitéplatz 1, 10117, Berlin, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe use of unattended automated office blood pressure (uAutoOBP) versus attended automated (aAutoOBP) and manual auscultatory office blood pressure (AuscOBP) measurements is a topic of current controversy.

aimTo evaluate the differences between OBP measurements methods in the general practice (GP) setting.

methodsWe first compared aAutoOBP and uAutoOBP in 42 consecutive patients with hypertension (group 1). Secondly, we compared AuscOBP to uAutoOBP measurements in 133 consecutive patients with hypertension (group 2). In addition, we analyzed the achieved OBP targets as recommended in the 2018 European Society of Cardiology (ESC) and the European Society of Hypertension (ESH) guidelines in group 2.

resultsThe mean age of patients in group 1 was 71 years (range 34-89 years, 54.8% females). The aAutoOBP and uAutoOBP systolic (131.7 and 131.6 mmHg) and diastolic (83.4 and 82.4 mmHg) mean values were not significantly different. The patient characteristics in group 2 were similar to group 1. We observed a significant difference between AuscOBP and uAutoOBP measurement for both systolic (149.4 versus 129.5 mm Hg) and diastolic (85.4 versus 81.6 mm Hg, p < 0.0001, respectively). Accordingly, 20.3% and 45.9% of patients reached the overall 2018 ESC/ESH systolic and diastolic OBP targets of < 140/80 mmHg according to AuscOBP and uAutoOBP (p < 0.0001).

conclusionThe attended versus unattended status of automated OBP measurements had no impact on OBP values in GP. However, significantly higher OBP values and lower rates of achieved target OBP were observed by using AuscOBP measurements by physicians in comparison to automated OBP recordings.

Indexed as

Blood PressureGeneral PracticeOffice VisitsAdultAgedAged, 80 and overAntihypertensive AgentsBlood Pressure DeterminationFemaleHumansHypertensionMaleMiddle AgedPredictive Value of TestsReproducibility of ResultsWhite Coat HypertensionAntihypertensive AgentsAutomated office blood pressureMobil-O-GraphOffice blood pressure measurementTarget office blood pressureWhite-coat effect