Towards 4D dedicated breast CT perfusion imaging of cancer: development and validation of computer simulated images.

Marco Caballo, Koen Michielsen, Christian Fedon, Ioannis Sechopoulos

Abstract readValidation Study
In one paragraph

Article in Physics in medicine and biology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Marco CaballoDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands.ORCID 0000-0002-3700-2785
Koen MichielsenDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands.
Christian FedonDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands.ORCID 0000-0002-5998-453X
Ioannis SechopoulosDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands.

Funding

Image Quality Improvement and Performance Assessment of Dedicated Breast CTR01CA181171 · NCI · STICHTING RADBOUD UNIVERSITAIR MEDISCH CENTRUM I.O. · PI SECHOPOULOS, IOANNIS · 2015 to 2020
$1.1M
NCI NIH HHS R01 CA181171
6 · The paper itself

Abstract

Dedicated breast CT is a fully tomographic breast imaging modality with potential for various applications throughout breast cancer care. If implemented to perform dynamic contrast-enhanced (CE) imaging (4D breast CT), it could be useful to obtain functional information at high combined spatio-temporal resolution. Before developing a 4D dedicated breast CT system, a computer simulation method for breast CT perfusion imaging is proposed. The simulation uses previously developed patient-based 4D digital breast phantoms, and generates realistic images with the selected acquisition parameters, allowing to investigate the effect of different acquisition settings on image quality. The simulation pipeline includes all steps of the image generation process, from ray tracing and scatter map generation, to the addition of realistic resolution losses and noise models. The pipeline was validated against experimental measurements performed on physical phantoms with a dedicated breast CT system, in terms of average error compared to ground truth projections (6.0%  ±  1.65%), Hounsfield unit (HU) values in a homogeneous phantom (acquired: -149 HU  ±  2 HU; simulated:  -140 HU  ±  2 HU), signal-to-noise ratio (SNR) (average error 6.7%  ±  4.2%), noise power spectra (NPS) (average error 4.3%  ±  2.5%), modulation transfer function (MTF) (average error 8.4%  ±  7.2%), and attenuation of different adipose/glandular equivalent mixtures (average error 6.9%  ±  4.0%) and glandular plus iodinated contrast medium concentrations equivalent mixtures (average error of 9.1%  ±  9.0%). 4D patient images were then simulated for different 4D digital breast phantoms at different air kerma levels to determine the effect of noise on the extracted tumor perfusion curves. In conclusion, the proposed pipeline could simulate images with a good level of realism, resulting in a tool that can be used for the design, development, and optimization of a 4D dedicated breast CT system.

Indexed as

Breast NeoplasmsComputer SimulationFemaleFour-Dimensional Computed TomographyHumansPerfusion ImagingPhantoms, ImagingSignal-To-Noise Ratio

Identifiers

PMID31703216
PMCPMC10424558

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.