Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 18 citations in OpenAlex.
- Comparison of 30° and 70° arthroscopes in canine hip arthroscopy: a 3D-printed model study.Veterinary research communications · 2026Article
- A Comparison of Two Surgical Treatment Methods for Atlantoaxial Instability in Dogs: Finite Element Analysis and a Canine Cadaver Study.Materials (Basel, Switzerland) · 2026Article
- Designing an Anatomical Plate to Improve Biomechanics and Stability for Distal Humerus Fractures: FEM Investigation and the Influence of Meshing Strategy.The archives of bone and joint surgery · 2026Article
- A 3D Printed Anatomically Pre-Contoured Plate for the Treatment of Y-T Humeral Condylar Fractures: A Feline Cadaveric Study.Animals : an open access journal from MDPI · 2024Article
- Database of segmentations and surface models of bones of the entire lower body created from cadaver CT scans.Scientific data · 2023Article
- Comprehensive personalized ankle joint shape analysis of children with cerebral palsy from pediatric MRI.Frontiers in bioengineering and biotechnology · 2022Article
- Convenient design method for customized implants based on bionic vein structure features.Frontiers in bioengineering and biotechnology · 2022Article
- Analyzing the Fitting of Novel Preformed Osteosynthesis Plates for the Reduction and Fixation of Mandibular Fractures.Journal of clinical medicine · 2021Article
- Thermal, Mechanical and Chemical Analysis of Poly(vinyl alcohol) Multifilament and Braided Yarns.Polymers · 2021Article
- Bone morphological feature extraction for customized bone plate design.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionIntra- and inter-population variations of bone morphology have made the process of designing an anatomically well-fitting fracture fixation plate challenging. Although statistical bone models have recently been used for analysing morphological variabilities, it is not known to what extent they would also provide the basis for the design of a new plate shape. This would be particularly valuable in the case where no existing plate shape is available to start the process of fit optimisation. Therefore, this study investigated the anatomical fitting of a plate shape (statistical plate) derived from the mean shape of a statistical 3D tibia bone model in comparison to results available from two other plate shapes.
methodsForty-five 3D bone models of tibiae from Japanese cadaver specimens, as well as 3D models of the plate undersurface of both a commercial and shape optimised Medial Distal Tibia Plate, were utilised from earlier studies. The mean shape of the 3D statistical bone model was generated from the tibia models utilising the Statismo framework. With reverse engineering software, the plate undersurface of the statistical plate shape was derived directly from the mean surface of the statistical 3D bone model. Through an iterative process, the statistical plate model was placed at the correct surgical position on each bone model for fit assessment.
resultsThe statistical plate was fitting for 20% of the tibiae compared to 13% for the commercial and 67% for the optimised plate, respectively.
conclusionsThe plate shape derived directly from a statistical bone model was fitting better than the commercial plate, but considerably inferior to that of an optimised plate. However, the results do clearly indicate that this approach provides an appropriate and solid basis for commencing shape optimisation of the statistical plate. Studies of other anatomical regions are required to confirm whether these findings can be generalised.