Smart pumps improve medication safety but increase alert burden in neonatal care.

Kristin R Melton, Kristen Timmons, Kathleen E Walsh, Jareen K Meinzen-Derr, Eric Kirkendall

Open access · goldAbstract read
In one paragraph

Article in BMC medical informatics and decision making, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Kristin R MeltonDivision of Neonatology and Pulmonary Biology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, 45229, USA. Kristin.melton@cchmc.org.ORCID 0000-0001-6170-0404
Kristen TimmonsDivision of Hospital Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
Kathleen E WalshDepartment of Pediatrics, College of Medicine, University of Cincinnati, Cincinnati, OH, USA.
Jareen K Meinzen-DerrDepartment of Pediatrics, College of Medicine, University of Cincinnati, Cincinnati, OH, USA.
Eric KirkendallDepartment of Pediatrics, College of Medicine, University of Cincinnati, Cincinnati, OH, USA.
Cincinnati Children's Hospital Medical Center · US

Funding

Improving Intensive Care Medication Safety through EHR-basedAlgorithms.R01LM012230 · NLM · CINCINNATI CHILDRENS HOSP MED CTR · PI KIRKENDALL, ERIC STEVEN, MELTON, KRISTIN · 2015 to 2018
$1.4M
NLM NIH HHS R01 LM012230
6 · The paper itself

Abstract

backgroundSmart pumps have been widely adopted but there is limited evidence to understand and support their use in pediatric populations. Our objective was to assess whether smart pumps are effective at reducing medication errors in the neonatal population and determine whether they are a source of alert burden and alert fatigue in an intensive care environment.

methodsUsing smart pump records, over 370,000 infusion starts for continuously infused medications used in neonates and infants hospitalized in a level IV NICU from 2014 to 2016 were evaluated. Attempts to exceed preset soft and hard maximum limits, percent variance from those limits, and pump alert frequency, patterns and salience were evaluated.

resultsSmart pumps prevented 160 attempts to exceed the hard maximum limit for doses that were as high as 7-29 times the maximum dose and resulted in the reprogramming or cancellation of 2093 infusions after soft maximum alerts. While the overall alert burden from smart pumps for continuous infusions was not high, alerts clustered around specific patients and medications, and a small portion (17%) of infusions generated the majority of alerts. Soft maximum alerts were often overridden (79%), consistent with low alert salience.

conclusionsSmart pumps have the ability to improve neonatal medication safety when compliance with dose error reducing software is high. Numerous attempts to administer high doses were intercepted by dosing alerts. Clustered alerts may generate a high alert burden and limit safety benefit by desensitizing providers to alerts. Future efforts should address ways to improve alert salience.

Indexed as

Infusion PumpsIntensive Care, NeonatalHumansInfant, NewbornMedication ErrorsRetrospective StudiesAlert fatigueInfusion pump alertsMedication administration errorsPatient safetySmart infusion pumps

Identifiers

PMID31699078
PMCPMC6836424
OpenAlexW2986485275