Evidence map›Paper›PMID 31697742›Full record

ArticlePloS one2019

Assessment of energy expenditure during high intensity cycling and running using a heart rate and activity monitor in young active adults.

Malgorzata Klass, Vitalie Faoro, Alain Carpentier

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Malgorzata KlassLaboratory for Biometry and Exercise Nutrition, Université Libre de Bruxelles (ULB), Brussels, Belgium.ORCID 0000-0003-1317-5945
Vitalie FaoroCardiopulmonary Exercise Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium.
Alain CarpentierLaboratory for Biometry and Exercise Nutrition, Université Libre de Bruxelles (ULB), Brussels, Belgium.
Université Libre de Bruxelles · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAlthough high intensity physical activities may represent a great proportion of the total energy expenditure in active people, only sparse studies have investigated the accuracy of wearable monitors to assess activity related energy expenditure (AEE) during high intensity exercises. Therefore, the purpose of the present study was to investigate the accuracy of the Actiheart, a light portable monitor estimating AEE based on heart rate (HR) and activity counts (ACT), during two popular activities (running and cycling) performed at high intensities. The benefit of an individual calibration of the HR-AEE relationship established during a preliminary maximal test was also evaluated.

methodsAEE was estimated in eighteen active adults (4 women and 14 men; 25 ± 4 yr) with indirect calorimetry using a respiratory gas analysis system (reference method) and the Actiheart during 5-min running and cycling at 60, 75 and 85% of maximal oxygen uptake (VO2max) previously determined during a maximal test performed on a treadmill or cycle ergometer. For the Actiheart, AEE was estimated either using the group or individual calibrated equations available in the dedicated software, and their respective HR, ACT or combined HR/ACT algorithms.

resultsWhen the HR algorithm was used for cycling and the HR or HR/ACT algorithms for running, AEE measured by the Actiheart increased proportionally to exercise intensity from 60 to 85% VO2max (P<0.001). Compared to indirect calorimetry, the Actiheart group calibrated equations slightly to moderately underestimated (3 to 20%) AEE for the three exercise intensities (P<0.001). Accuracy of AEE estimation was greatly improved by individual calibration of the HR-AEE relationship (underestimation below 5% and intraclass correlation coefficient [ICC]: 0.79-0.93) compared to group calibration (ICC: 0.64-0.79).

conclusionThe Actiheart enables to assess AEE during high intensity running and cycling when the appropriate algorithm is applied. Since an underestimation was present for group calibration, an individual and sport-specific calibration should be performed when a high accuracy is required.

Indexed as

Energy MetabolismAdultAlgorithmsCalorimetry, IndirectExercise TestFemaleFitness TrackersHealthy VolunteersHeart RateHumansMaleOxygen ConsumptionRunningWearable Electronic DevicesYoung Adult

Identifiers

PMID31697742
PMCPMC6837421
OpenAlexW2986831696

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.