Evidence map›Paper›PMID 31696437›Full record

ArticleCardiology and therapy2020

Comparison of Cardiac Repolarization After Transcatheter Aortic Valve Implantation and Surgical Aortic Valve Replacement: A Longitudinal Study.

Satoru Chino, Eriko Yamanaka, Toshifumi Takasusuki, Shinsuke Hamaguchi, Shigeki Yamaguchi

Open access · goldAbstract read
In one paragraph

Article in Cardiology and therapy, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 76% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Satoru ChinoDepartment of Anesthesiology, School of Medicine, Dokkyo Medical University, Kitakobayashi 880, Mibu, Tochigi, 321-0293, Japan.
Eriko YamanakaDepartment of Anesthesiology, School of Medicine, Dokkyo Medical University, Kitakobayashi 880, Mibu, Tochigi, 321-0293, Japan.
Toshifumi TakasusukiDepartment of Anesthesiology, School of Medicine, Dokkyo Medical University, Kitakobayashi 880, Mibu, Tochigi, 321-0293, Japan. takasusu@dokkyomed.ac.jp.
Shinsuke HamaguchiDepartment of Anesthesiology, School of Medicine, Dokkyo Medical University, Kitakobayashi 880, Mibu, Tochigi, 321-0293, Japan.
Shigeki YamaguchiDepartment of Anesthesiology, School of Medicine, Dokkyo Medical University, Kitakobayashi 880, Mibu, Tochigi, 321-0293, Japan.
Dokkyo Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionTranscatheter aortic valve implantation (TAVI) has been established as an alternative to surgical aortic valve replacement (SAVR) for high-risk patients. To assess the impact of TAVI on cardiac repolarization, we compared QT dispersion (QTD) and the interval from the peak to the end of the T wave (Tpeak-Tend: TpTe) between the patients who underwent TAVI and those who underwent SAVR and TpTe between the patients who underwent TAVI or SAVR.

methodsThis retrospective study was approved by the ethics committee of Dokkyo Medical University Hospital. The study included 45 patients who underwent TAVI and 45 patients who underwent SAVR. The QT, corrected QT (QTc), QTD, QTc dispersion (QTcD), Tp-Te, Tp-Te/QT, and Tp-Te/QTc were manually measured in standard 12-lead electrocardiogram (ECG) recordings obtained before surgery, immediately after surgery, 1 month, 3 months, and 6 months after surgery and compared between the two groups.

resultsNo change was observed in RR, QT, QTc, Tp-Te, Tp-Te/QT, and Tp-Te/QTc in the two groups throughout the study. The QTD and QTcD significant decreased immediately after surgery in the TAVI group as compared to the SAVR group (P < 0.001). In contrast, QTD and QTcD in the SAVR group gradually, but not significantly declined 6 months after surgery.

conclusionsQTD and QTcD immediately decreased after TAVI as compared to SAVR. Our findings indicate that TAVI more rapidly improved dispersion of spatial repolarization than SAVR.

Indexed as

Cardiac repolarizationQT dispersionSurgical aortic valve replacementTpeak–TendTranscatheter aortic valve implantation

Identifiers

PMID31696437
PMCPMC7237665
OpenAlexW2985194051

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.