ArticleEJIFCC2019
Evaluation of Visual Serum Indices Measurements and Potential False Result Risks in Routine Clinical Chemistry Tests in Addis Ababa, Ethiopia.
Article in EJIFCC, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- The Effect of Hemolysis on Biochemical Tests: Determining Interference Cutoffs and Managing Hemolytic Samples.Journal of analytical methods in chemistry · 2026Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSerum indices (SI) including hemolyzed, lipemic, and icteric samples, affects the accuracy of test result. The aim of this study was to evaluate SI values done by visual inspections and potential false result risks by comparing with actual measurements done by Cobas 6000 Chemistry analyzer at Ethiopian Public Health Institute (EPHI), Addis Ababa, Ethiopia.
methodsAn observational, cross-sectional study was conducted from April to May 2017 on samples referred to Clinical Chemistry laboratory of EPHI, Ethiopia. These samples SI values, after visual inspection by three trained observers, was analyzed again on Roche Cobas 6000 analyzer (RCA). The generated data was analyzed by using weighted kappa methods on STAT statistical software version 20.
resultsFrom a total of 1509 samples, SI values identified by the RCA as hemolysis, icteric, and lipemic were 933 (62%), 74(5%) and 59(4%) respectively. The SI average weighted kappa between RCA and visual inspection were: 0.1870, 0.3421, and 0.1259 for hemolysis, icteric, and lipemic samples, respectively. Combined inter-observers variability among observers for hemolysis, Icterus, and lipemic samples were 0.4758, 0.3258, and 0.3628 respectively. The best agreement among observers was in the case of hemolysis (0 grades), while the lowest agreement was observed in the case of icterus (+3 grades). In addition, test parameters, such as CK-MB (22%), and LDH (20%) were falsely accepted, whereas Cl
conclusionVisual inspection of SI showed poorly agreement with automated system. Thus, there is genuine need for more training of Laboratory professionals on identification of SI, and as much as possible SI should be done by automated system to improve quality of test results.
Indexed as
Identifiers
31695585PMC6803774What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.