Evidence map›Paper›PMID 31695399›Full record

Observational studyVascular health and risk management2019

Real-World Use Of Ultrathin-Strut Biodegradable Polymer-Coated Sirolimus-Eluting Stents In Patients With Coronary Artery Disease: 6-Month Clinical Outcomes.

Prakash Ajmera, Ramesh Pothineni, Kamal Kumar Chawla, Sai Sudhakar Mantravadi, Pankaj Vinod Jariwala, Vinod Vijan, Vikrant Vijan

Abstract readMulticenter StudyObservational StudyVideo-Audio Media
In one paragraph

Observational study in Vascular health and risk management, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Prakash AjmeraDepartment of Cardiology, Malla Reddy Narayana Multispeciality Hospital, Hyderabad, Telangana 500055, India.
Ramesh PothineniDepartment of Cardiology, Ramesh Hospitals, Vijayawada, Andhra Pradesh 520008, India.
Kamal Kumar ChawlaDepartment of Cardiology, Malla Reddy Narayana Multispeciality Hospital, Hyderabad, Telangana 500055, India.
Sai Sudhakar MantravadiDepartment of Cardiology, Gleneagles Global Hospital, Hyderabad, Telangana 500004, India.
Pankaj Vinod JariwalaDepartment of Cardiology, Yashoda Hospitals, Somajiguda, Hyderabad, Telangana, 500082, India.ORCID 0000-0003-1747-9276
Vinod VijanDepartment of Cardiology, Vijan Cardiac and Critical Care Centre, Nashik, Maharashtra 422005, India.
Vikrant VijanDepartment of Cardiology, Vijan Cardiac and Critical Care Centre, Nashik, Maharashtra 422005, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAlthough a number of drug-eluting stents have been developed with different design, composition, and polymers, the search for an ideal drug-eluting stent is ongoing. The Tetriflex (Sahajanand Medical Technology, Surat, India) is a newer-generation, ultrathin (60 µm) biodegradable polymer-coated sirolimus-eluting stent (SES) designed with a unique long dual Z-link on a cobalt-chromium alloy. The present registry aimed to evaluate the safety and clinical outcomes of the Tetriflex SES at 6-month post-implantation.

methodsThis was an investigator-initiated, retrospective, multicenter, single-arm, observational registry conducted at five tertiary-care centers in India. A total of 1,269 consecutive patients with coronary artery disease who underwent implantation of at least one Tetriflex SES between March 2017 and March 2018 were included. The primary outcome was considered a composite of cardiac death, myocardial infarction and target-lesion revascularization (TLR) at 6-month follow-up. Stent thrombosis was evaluated as a safety outcome at 6-month follow-up.

resultsThe mean age of patients was 54.99±10.80 years. Among 1,515 lesions treated with 1,682 Tetriflex SES, 58.3% were type C lesions. Six-month follow-up was done for 1,245 of 1,269 (98.1%) patients. At 6 months, composite events had occurred in 31 (2.5%) patients, consisting of ten (0.8%) cardiac deaths, 16 (1.3%) myocardial infarctions, and five (0.4%) TLRs. Stent thrombosis was observed in seven (0.56%) cases at 6 months. A subgroup analysis between diabetic and nondiabetic patients did not reveal any statistically significant difference for clinical outcomes at 6-month follow-up.

conclusionThe results of the current registry outline the safety and effectiveness of the Tetriflex SES in real-world patients, as it displayed favorable clinical outcomes at 6-month follow-up, with low incidence of TLR and stent thrombosis.

Indexed as

Coated Materials, BiocompatibleDrug-Eluting StentsAdultCardiovascular AgentsCoronary Artery DiseaseCoronary OcclusionCoronary ThrombosisFemaleHumansIncidenceIndiaMaleMiddle AgedPercutaneous Coronary InterventionProsthesis DesignRegistriesCardiovascular AgentsCoated Materials, BiocompatibleSirolimusbiodegradable polymerdrug-eluting stentssirolimusultrathin strut

Identifiers

PMID31695399
PMCPMC6805243

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.