ArticleJournal of diabetes science and technology2020
A Simulation Study to Assess the Effect of Analytic Error on Neonatal Glucose Measurements Using the Canadian Pediatric Society Position Statement Action Thresholds.
Article in Journal of diabetes science and technology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 8 citations in OpenAlex.
- Burden of "Pokes" in Newborns With Hypoglycemia Who Require IV Dextrose.Hospital pediatrics · 2025Article
- The clinical effect of glucose meter selection upon the detection of neonatal hypoglycemia.Paediatrics & child health · 2022Article
- Strategies to improve neurodevelopmental outcomes in babies at risk of neonatal hypoglycaemia.The Lancet. Child & adolescent health · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe Canadian Pediatric Society (CPS) has endorsed an algorithm for the screening and immediate management of babies at risk of neonatal hypoglycemia that provides time-dependent glucose concentration action thresholds. The objective of this study was to evaluate the impact of glucose analytic error (bias and imprecision) on the misclassification of glucose meter results from a neonatal intensive care unit (NICU) using the CPS guidelines.
methodsA simulation dataset of true glucose values (
resultsMeasurement biases ranging from -20 to +20 mg/dL combined with coefficients of variation 0% to 20% were evaluated to predict misclassification rates at 32, 36, and 47 mg/dL. The models demonstrated low risk of false normoglycemia-at 5% CV and +10 mg/dL bias: 0.8% to 5% misclassification at the 32 and 47 mg/dL thresholds due to bias. The models demonstrated risk of false hypoglycemia-at 5% CV and -10 mg/dL bias: 3% to 12.5% misclassification at 32 and 47 mg/dL thresholds due to both bias and imprecision.
conclusionUsing CPS action thresholds, the simulation model predicted the proportion of neonates at risk of inappropriate clinical action-both of omission or "failure to treat" and commission or "overtreatment" in response to NICU glucose meter results at specific bias and imprecision values.
Indexed as