Evidence map›Paper›PMID 31693688›Full record

ArticlePloS one2019

Contactless monitoring of heart and respiratory rate in anesthetized pigs using infrared thermography.

Carina Barbosa Pereira, Henriette Dohmeier, Janosch Kunczik, Nadine Hochhausen, René Tolba, Michael Czaplik

Abstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Effects of dietary yeast β-glucan on lactating sows under heat stress.Journal of animal science and technology · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Review
  18. Article
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Carina Barbosa PereiraDepartment of Anesthesiology, Faculty of Medicine, RWTH Aachen University, Aachen, NRW, Germany.ORCID 0000-0003-1788-4562
Henriette DohmeierDepartment of Anesthesiology, Faculty of Medicine, RWTH Aachen University, Aachen, NRW, Germany.
Janosch KunczikDepartment of Anesthesiology, Faculty of Medicine, RWTH Aachen University, Aachen, NRW, Germany.
Nadine HochhausenDepartment of Anesthesiology, Faculty of Medicine, RWTH Aachen University, Aachen, NRW, Germany.
René TolbaInstitute for Laboratory Animal Science and Experimental Surgery, Faculty of Medicine, RWTH Aachen University, Aachen, NRW, Germany.
Michael CzaplikDepartment of Anesthesiology, Faculty of Medicine, RWTH Aachen University, Aachen, NRW, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pig experiments have played an important role in medical breakthroughs during the last century. In fact, pigs are one of the major animal species used in translational research, surgical models and procedural training due to their anatomical and physiological similarities to humans. To ensure high bioethical standards in animal trials, new directives have been implemented, among others, to refine the procedures and minimize animals' stress and pain. This paper presents a contactless motion-based approach for monitoring cardiorespiratory signals (heart rate and respiratory rate) in anesthetized pigs using infrared thermography. Heart rate monitoring is estimated by measuring the vibrations (precordial motion) of the chest caused by the heartbeat. Respiratory rate, in turn, is computed by measuring the mechanical chest movements that accompany the respiratory cycle. To test the feasibility of this approach, thermal videos of 17 anesthetized pigs were acquired and analyzed. A high agreement between infrared thermography and a gold standard (electrocardiography and capnography-derived respiratory rate) was achieved. The mean absolute error averaged 3.43 ± 3.05 bpm and 0.27 ± 0.48 breaths/min for heart rate and respiratory rate, respectively. In sum, infrared thermography is capable of assessing cardiorespiratory signals in pigs. Future work should be conducted to evaluate infared thermography capability of capturing information for long term monitoring of research animals in a diverse set of facilities.

Indexed as

Animal ExperimentationAnimalsAnimal WelfareFeasibility StudiesHeart RateInfrared RaysModels, AnimalMonitoring, PhysiologicRespiratory RateSignal Processing, Computer-AssistedSwineThermography

Identifiers

PMID31693688
PMCPMC6834247

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.