Evidence map›Paper›PMID 31689196›Full record

ArticleIEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society2019

Intraoperative Responses May Predict Chronic Performance of Composite Flat Interface Nerve Electrodes on Human Femoral Nerves.

Max J Freeberg, Rahila Ansari, Gilles C J Pinault, Lisa M Lombardo, Michael E Miller, Dustin J Tyler, Ronald J Triolo

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Chronic nerve health following implantation of femoral nerve cuff electrodes.Journal of neuroengineering and rehabilitation · 2020
    Article
  6. Sum of phase-shifted sinusoids stimulation prolongs paralyzed muscle output.Journal of neuroengineering and rehabilitation · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Max J Freeberg
Rahila Ansari
Gilles C J Pinault
Lisa M Lombardo
Michael E Miller
Dustin J Tyler
Ronald J Triolo
Louis Stokes Cleveland VA Medical Center · USCase Western Reserve University · US

Funding

MEDICAL SCIENTIST TRAINING PROGRAMT32GM007250 · NIGMS · CASE WESTERN RESERVE UNIVERSITY · PI HUANG, ALEX YEE-CHEN · 1985 to 2023
$33.4M
Automatic Control of Standing Balance with Functional Neuromuscular StimulationR01NS040547 · NINDS · CASE WESTERN RESERVE UNIVERSITY · PI AUDU, MUSA L, TRIOLO, RONALD J · 2000 to 2022
$7.2M
Integrated Neural Engineering and Rehabilitation Training ProgramT32EB004314 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI Jeffrey R Capadona, Robert F. Kirsch · 2004 to 2026
$6.1M
NEUROPROSTHESIS PERFORMANCE - NERVE CUFF ELECTRODESR01EB001889 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI TRIOLO, RONALD J, TYLER, DUSTIN J. · 2003 to 2017
$5.9M
NRSA Training CoreTL1TR002549 · NCATS · CASE WESTERN RESERVE UNIVERSITY · PI HARDING, CLIFFORD V · 2018 to 2022
$2.9M
Clinical and Translational Science Collaborative of ClevelandTL1TR000441 · NCATS · CASE WESTERN RESERVE UNIVERSITY · PI KONSTAN, MICHAEL W. · 2012 to 2016
$2.8M
Advanced Platform Technology Center of ExcellenceI50RX001871 · VA · LOUIS STOKES CLEVELAND VA MEDICAL CENTER · PI MARGOT S. DAMASER, Gilles Pinault · 2015 to 2026
–
Exploiting Selective Recruitment to Prolong Standing after SCII01RX001039 · VA · LOUIS STOKES CLEVELAND VA MEDICAL CENTER · PI TRIOLO, RONALD J, TYLER, DUSTIN J. · 2015 to 2019
–
NCATS NIH HHS TL1 TR000441NCATS NIH HHS TL1 TR002549NIBIB NIH HHS R01 EB001889NIBIB NIH HHS T32 EB004314NIGMS NIH HHS T32 GM007250NINDS NIH HHS R01 NS040547RRD VA I01 RX001039RRD VA I50 RX001871RRD VA IK6 RX003844
6 · The paper itself

Abstract

Peripheral nerve cuff electrodes (NCEs) in motor system neuroprostheses can generate strong muscle contractions and enhance surgical efficiency by accessing multiple muscles from a single proximal location. Predicting chronic performance of high contact density NCEs based on intraoperative observations would facilitate implantation at locations that maximize selective recruitment, immediate connection of optimal contacts to implanted pulse generators (IPGs) with limited output channels, and initiation of postoperative rehabilitation as soon as possible after surgery. However, the stability of NCE intraoperative recruitment to predict chronic performance has not been documented. Here we report the first-in-human application of a specific NCE, the composite flat interface nerve electrode (C-FINE), at a new and anatomically challenging location on the femoral nerve close to the inguinal ligaments. EMG and moment recruitment curves were recorded for each of the 8 contacts in 2 C-FINE intraoperatively, perioperatively, and chronically for 6 months. Intraoperative measurements predicted chronic outcomes for 87.5% of contacts with 14/16 recruiting the same muscles at 6 months as intraoperatively. In both 8-contact C-FINEs, 3 contacts elicited hip flexion and 5 selectively generated knee extension, 3 of which activated independent motor unit populations each sufficient to support standing. Recruitment order stabilized in less than 3 weeks and did not change thereafter. While confirmation of these results will be required with future studies and implant locations, this suggests that remobilization and stimulated exercise may be initiated 3 weeks after surgery with little risk of altering performance.

Indexed as

Electrodes, ImplantedFemoral NerveNeural ProsthesesProsthesis ImplantationElectric StimulationElectromyographyHipHumansIntraoperative PeriodKneeMonitoring, IntraoperativeMotor NeuronsMovementMuscle Fibers, SkeletalPredictive Value of TestsSpinal Cord Injuries

Identifiers

PMID31689196
PMCPMC6938031
OpenAlexW2989393492

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.